Product Approval Menu > Application Detail
 
FL # FL5414-R38
Application Type Editorial Change
Code Version 2023
Application Status Approved
  *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
 
Comments
Archived
 
Product Manufacturer Simonton
Address/Phone/Email 5020 Weston Parkway
Suite 300
Cary, NC 27513
(614) 307-3278
luanne.harris@cornerstone-bb.com
 
Authorized Signature Luanne Harris
luanne.harris@cornerstone-bb.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative AAMA
Address/Phone/Email 1827 Walden Office Square
Suite 550
Schaumburg, IL 60173
(847) 303-5664
webmaster@aamanet.org
 
Category Windows
Subcategory Single Hung
 
Compliance Method Certification Mark or Listing
 
Certification Agency Fenestration and Glazing Industry Alliance (formerly AAMA)
Validated By Fenestration and Glazing Industry Alliance (formerly AAMA)
 
 
 
Referenced Standard and Year (of Standard)
StandardYear
AAMA/WDMA/CSA 101/I.S 2/A4402011
 
Equivalence of Product Standards
Certified By

 
 
 
 
Product Approval Method Method 1 Option A
 
Date Submitted 07/14/2026
Date Validated 07/17/2026
Date Pending FBC Approval
Date Approved 07/23/2026
 
Summary of Products
FL # Model, Number or Name Description
5414.1 41-18 ProFinish Brickmould 300, PerfeXion BM 300 Vinyl Single Hung
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: N/A
 Other: 48x80 (+/-25 PSF), 53x71 (+/-30 PSF), 44x63 (+/-35 PSF), 48x72 (+/-40 PSF), 36x63 (+/-45 PSF), 44x63 (+/-45 PSF), 36x76 (+/-50 PSF)
Certification Agency Certificate
 FL5414_R38_C_CAC_41-18 SH (7563)-PG30.pdf
 FL5414_R38_C_CAC_41-18 SH (7583)-PG50.pdf
 FL5414_R38_C_CAC_41-18 SH (7584)-PG25.pdf
 FL5414_R38_C_CAC_41-18 SH (7585)-PG45.pdf
 FL5414_R38_C_CAC_41-18 SH (7586)-PG35.pdf
 FL5414_R38_C_CAC_41-18 SH 44x63 (8954).pdf
 FL5414_R38_C_CAC_41-18 SH 48x72 (8889).pdf
Quality Assurance Contract Expiration Date
 09/26/2030
Installation Instructions
 FL5414_R38_II_IN0228-R9 2X.pdf
 FL5414_R38_II_IN0285-R4 1X.pdf
 Verified By: Fenestration and Glazing Industry Alliance (formerly AAMA)
 Created by Independent Third Party: 
Evaluation Reports
 FL5414_R38_AE_EvalReport-IN0285-R4.pdf
 Created by Independent Third Party: Yes
5414.2 41-18 ProFinish Brickmould 300, PerfeXion BM 300 Vinyl Twin Single Hung
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: N/A
 Other: 96x80 (+/-25 PSF), 89x63 (+/-30 PSF), 73x74 (+/-45 PSF), 73x74 (+/-50 PSF)
Certification Agency Certificate
 FL5414_R38_C_CAC_41-18 SH Twin (10599) 73x74 PG50.pdf
 FL5414_R38_C_CAC_41-18 SH Twin (7582)-PG45.pdf
 FL5414_R38_C_CAC_41-18 SH Twin (9210) 96x80 PG25.pdf
 FL5414_R38_C_CAC_41-18 SH Twin (9211) 89x63 PG30.pdf
Quality Assurance Contract Expiration Date
 09/27/2030
Installation Instructions
 FL5414_R38_II_IN0230-R7 2X.pdf
 Verified By: Fenestration and Glazing Industry Alliance (formerly AAMA)
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
5414.3 41-18 ProFinish Brickmould 300, PerfeXion BM 300 Vinyl Triple Single Hung
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: N/A
 Other: 109x63 (+/-35 PSF) or 109x72 (+/-45 PSF)
Certification Agency Certificate
 FL5414_R38_C_CAC_41-18 SH Triple (10600) 109x72 PG45.pdf
 FL5414_R38_C_CAC_41-18 SH Triple (8669)-PG35.pdf
Quality Assurance Contract Expiration Date
 03/13/2027
Installation Instructions
 FL5414_R38_II_IN0232-R7 2X.pdf
 Verified By: Fenestration and Glazing Industry Alliance (formerly AAMA)
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
5414.4 43-06 / 43-17 6060, ProFinish Contractor, PerfeXion Contractor Vinyl Single Hung & Operating Arches
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: N/A
 Other: 36x72 (+/-25 PSF), 48x80 (+/-25 PSF), 36x63 (+/- 45 PSF) 44x63 (+/-35 PSF), 36x74 (+/-35 PSF), 53x71 (+/-35 PSF), 48x72 (+/-40 PSF), 44x63 (+/-45 PSF), 36x84 (+/-50 PSF), 36x74 (+/-50 PSF), 32x62 (+/-50 PSF), 44x75 (+/-30)
Certification Agency Certificate
 FL5414_R38_C_CAC_043-06 SH (Fin) (10380) 36x73 PG50.pdf
 FL5414_R38_C_CAC_43-06 SH (10388) 36x74 PG50.pdf
 FL5414_R38_C_CAC_43-06 SH (Fin) (10155) 44x63 PG35.pdf
 FL5414_R38_C_CAC_43-06 SH (Fin) (10159) 36x74 PG35.pdf
 FL5414_R38_C_CAC_43-06 SH (Fin) (10387) 44x63 PG45.pdf
 FL5414_R38_C_CAC_43-06 SH (Fin) (11896) 44x75 LC-PG30.pdf
 FL5414_R38_C_CAC_43-06 SH (Fin) (7394)-PG35.pdf
 FL5414_R38_C_CAC_43-06 SH (Fin) (8882)-PG45.pdf
 FL5414_R38_C_CAC_43-06 SH (Fin) (9206) 36x72 PG25.pdf
 FL5414_R38_C_CAC_43-06 SH (Fin) (9207) 32x62 PG50.pdf
 FL5414_R38_C_CAC_43-06 SH (Fin) (9208) 48x80 PG25.pdf
 FL5414_R38_C_CAC_43-06 SH (Fin-Finless) (9970) 48x72 PG40.pdf
 FL5414_R38_C_CAC_43-06 SH (Fin-Finless) (9971) 36x84 PG50.pdf
 FL5414_R38_C_CAC_43-06 SH (Finless) (11782)-PG35.pdf
 FL5414_R38_C_CAC_43-17 SH (Fin) (9164) 48x80 PG25.pdf
 FL5414_R38_C_CAC_43-17 to 43-06 Waiver.pdf
Quality Assurance Contract Expiration Date
 01/28/2027
Installation Instructions
 FL5414_R38_II_IN0160-R13 2X.pdf
 FL5414_R38_II_IN0242-R9 1X.pdf
 FL5414_R38_II_IN0600-R1 2X.pdf
 Verified By: Fenestration and Glazing Industry Alliance (formerly AAMA)
 Created by Independent Third Party: 
Evaluation Reports
 FL5414_R38_AE_EvalReport-IN0242-R9.pdf
 Created by Independent Third Party: Yes
5414.5 43-17 ProFinish Contractor, PerfeXion Contractor Vinyl Single Hung
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: N/A
 Other: 48x80 (+/-25 PSF), 44x63 (+/-35 PSF), 36x76 (+/-50 PSF), 36x96 (+/-50 PSF), 44x96 (+/-20 PSF)
Certification Agency Certificate
 FL5414_R38_C_CAC_43-17 SH (10873) 48x80 PG25.pdf
 FL5414_R38_C_CAC_43-17 SH (10874) 44x96 PG20.pdf
 FL5414_R38_C_CAC_43-17 SH (11338) 36x96 PG50.pdf
 FL5414_R38_C_CAC_43-17 SH (Fin) (9162) 44x63 PG35.pdf
 FL5414_R38_C_CAC_43-17 SH (Fin) (9163) 36x76 PG50.pdf
Quality Assurance Contract Expiration Date
 04/24/2027
Installation Instructions
 FL5414_R38_II_IN0162-R13 2X.pdf
 FL5414_R38_II_IN0244-R7 1X.pdf
 Verified By: Fenestration and Glazing Industry Alliance (formerly AAMA)
 Created by Independent Third Party: 
Evaluation Reports
 FL5414_R38_AE_EvalReport-IN0244-R7.pdf
 Created by Independent Third Party: Yes
5414.6 43-17 ProFinish Contractor, PerfeXion Contractor Vinyl Twin Single Hung
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: N/A
 Other: 89x63 (+/-30 PSF), 73x63 (+/-35 PSF), 73x74 (+/-45 PSF)
Certification Agency Certificate
 FL5414_R38_C_CAC_43-17 SH Twin (10852) 73x74 PG45.pdf
 FL5414_R38_C_CAC_43-17 SH Twin (9204) 73x63 PG35.pdf
 FL5414_R38_C_CAC_43-17 SH Twin (9205) 89x63 PG30.pdf
Quality Assurance Contract Expiration Date
 04/25/2027
Installation Instructions
 FL5414_R38_II_IN0161-R7 2X.pdf
 FL5414_R38_II_IN0246-R5 1X.pdf
 Verified By: Fenestration and Glazing Industry Alliance (formerly AAMA)
 Created by Independent Third Party: 
Evaluation Reports
 FL5414_R38_AE_EvalReport-IN0246-R5.pdf
 Created by Independent Third Party: Yes
5414.7 43-17 ProFinish Contractor, PerfeXion Contractor Vinyl Triple Single Hung
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +35/-35
 Other: 109" x 63"
Certification Agency Certificate
 FL5414_R38_C_CAC_43-17 SH Triple (10628).pdf
 FL5414_R38_C_CAC_43-17 SH Triple (8554).pdf
Quality Assurance Contract Expiration Date
 04/04/2031
Installation Instructions
 FL5414_R38_II_IN0248-R5 1X.pdf
 Verified By: Fenestration and Glazing Industry Alliance (formerly AAMA)
 Created by Independent Third Party: 
Evaluation Reports
 FL5414_R38_AE_EvalReport-IN0248-R5.pdf
 Created by Independent Third Party: Yes
5414.8 43-17 (Sunroom) ProFinish Contractor, PerfeXion Contractor Vinyl Single Hung for Sunrooms
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: N/A
 Other: 36x96 (+/-50 PSF), 44x63 (+/-35 PSF), 48x80 (+/-25 PSF)
Certification Agency Certificate
 FL5414_R38_C_CAC_43-17 SH (10873) 48x80 PG25.pdf
 FL5414_R38_C_CAC_43-17 SH (11338) 36x96 PG50.pdf
 FL5414_R38_C_CAC_43-17 SH (Fin) (9162) 44x63 PG35.pdf
Quality Assurance Contract Expiration Date
 04/24/2027
Installation Instructions
 FL5414_R38_II_IN0528-R4 SH SUNROOM.pdf
 Verified By: Fenestration and Glazing Industry Alliance (formerly AAMA)
 Created by Independent Third Party: 
Evaluation Reports
 FL5414_R38_AE_PER10037.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex