| 15304.1 |
Aluminum Clad Wood Fixed Casement |
Aluminum Clad Wood Fixed Casement (94_1/2" x 59") |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +55/-55 Other: Class CW-PG55; Size Tested 2400mm x 1500mm (94_1/2" x 59") Type-FW; Water Test Press 730Pa (15.04psf); Can. Air Infil/Exfil. Level=Fixed. Glass meets current version of ASTM E1300. |
Certification Agency Certificate FL15304_R8_C_CAC_NI010946-R4.pdf Quality Assurance Contract Expiration Date 12/31/2026 Installation Instructions FL15304_R8_II_FBC 2026 Section 1711 Installation Statement.pdf FL15304_R8_II_MC_CAF_FL_Install_Drawings_-_28B23.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 15304.2 |
Aluminum Clad Wood Fixed Casement |
Aluminum Clad Wood Fixed Casement (47_1/4" x 47_1/4") |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +80/-80 Other: Class CW-PG80; Size Tested 1200mm x 1200mm (47_1/4" x 47_1/4") Type-FW; Water Test Press 730Pa (15.04psf); Can. Air Infil/Exfil. Level=Fixed. Glass meets current version of ASTM E1300. |
Certification Agency Certificate FL15304_R8_C_CAC_NI010946.01-R4.pdf Quality Assurance Contract Expiration Date 12/31/2026 Installation Instructions FL15304_R8_II_FBC 2026 Section 1711 Installation Statement.pdf FL15304_R8_II_MC_CAF_FL_Install_Drawings_-_28B23.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 15304.3 |
Aluminum Clad Wood Fixed Casement |
Aluminum Clad Wood Fixed Casement (105" x 96") |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +55/-55 Other: Class CW-PG55; Size Tested 2667mm x 2458mm (105" x 96") Type-FW; Water Test Press 720Pa (15.04psf); Can. Air Infil/Exfil. Level=Fixed. Glass meets current version of ASTM E1300. |
Certification Agency Certificate FL15304_R8_C_CAC_NI013235-R2.pdf Quality Assurance Contract Expiration Date 06/30/2027 Installation Instructions FL15304_R8_II_FBC 2026 Section 1711 Installation Statement.pdf FL15304_R8_II_MC_CAF_FL_Install_Drawings_-_28B23.pdf Verified By: National Accreditation & Management Institute Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |