Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL15302-R7
Application Type Affirmation
Code Version 2023
Application Status Approved
  *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
 
Comments
Archived
 
Product Manufacturer Loewen Windows
Address/Phone/Email 77 Hwy 52 West
Steinbach, NON-US 00000
(431) 305-0888   Ext 5398
nicholasmazerolle@loewen.com
 
Authorized Signature Mazerolle Nicholas
nicholasmazerolle@loewen.com
 
Technical Representative Steve Brand
Address/Phone/Email 77 Highway 52 West
Steinbach, NON-US 00000
(431) 305-0888   Ext 5651
stevebrand@loewen.com
 
Quality Assurance Representative Eric Teichroeb
Address/Phone/Email 77 Highway 52 West
Steinbach, NON-US 00000
(431) 305-0888   Ext 5301
ericteichroeb@loewen.com
 
Category Windows
Subcategory Awning
 
Compliance Method Certification Mark or Listing
 
Certification Agency National Accreditation & Management Institute
Validated By National Accreditation & Management Institute
 
 
 
Referenced Standard and Year (of Standard)
StandardYear
AAMA/WDMA/CSA 101/I.S.2/A440-082008
AAMA/WDMA/CSA 101/I.S.2/A440-112011
 
Equivalence of Product Standards
Certified By

 
 
 
Documentation from approved Evaluation or Validation Entity
 
 
Product Approval Method Method 1 Option A
 
Date Submitted 11/17/2023
Date Validated 11/17/2023
Date Pending FBC Approval
Date Approved 11/29/2023
Date Revised 07/30/2026
 
Summary of Products
FL # Model, Number or Name Description
15302.1 Aluminum Clad Wood Awning Aluminum Clad Wood Awning (47_1/4" x 31_1/2")
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +95/-95
 Other: Class CW-PG95; Size Tested 1200mm x 800mm (47 1/4" x 31 1/2") Type-AP; Water Test Press 730Pa (15.0psf); CDN. Air Infil/Exfil. Level=A3. Glass meets the requirements of ASTM E1300.
Certification Agency Certificate
 FL15302_R7_C_CAC_NI010961.01-R3.pdf
Quality Assurance Contract Expiration Date
 12/31/2026
Installation Instructions
 FL15302_R7_II_MC_AW_ROTO_FL_Install_Drawings_-_28B28.pdf
 Verified By: National Accreditation & Management Institute
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
15302.2 Aluminum Clad Wood Awning Aluminum Clad Wood Awning (63" x 39_3/8")
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +65/-65
 Other: Class CW-PG65; Size Tested 1600mm x 1000mm (63" x 39 3/8") Type-AP; Water Test Press 730Pa (15.0psf); CDN. Air Infil/Exfil. Level=A3. Glass meets the requirements of ASTM E1300.
Certification Agency Certificate
 FL15302_R7_C_CAC_NI010961-R3.pdf
Quality Assurance Contract Expiration Date
 12/31/2026
Installation Instructions
 FL15302_R7_II_MC_AW_ROTO_FL_Install_Drawings_-_28B28.pdf
 Verified By: National Accreditation & Management Institute
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
15302.3 Aluminum Clad Wood Awning Aluminum Clad Wood Awning (67" x 53")
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +50/-50
 Other: Class LC-PG50; Size Tested 1700mm x 1350mm (67" x 53") Type-AP; Water Test Press 720Pa (15.0psf); CDN. Air Infil/Exfil. Level=A3. Glass meets the requirements of ASTM E1300.
Certification Agency Certificate
 FL15302_R7_C_CAC_NI013177.02-R2.pdf
Quality Assurance Contract Expiration Date
 02/28/2027
Installation Instructions
 FL15302_R7_II_MC_AW_ROTO_FL_Install_Drawings_-_28B28.pdf
 Verified By: National Accreditation & Management Institute
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
15302.4 Aluminum Clad Wood Push-Out Awning Aluminum Clad Wood Push-Out Awning (67" x 53")
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +45/-45
 Other: Class CW-PG45; Size Tested 1700mm x 1350mm (67" x 53") Type-AP; Water Test Press 720Pa (15.0psf); CDN. Air Infil/Exfil. Level=A3. Glass meets the requirements of ASTM E1300.
Certification Agency Certificate
 FL15302_R7_C_CAC_NI013177.04-R3.pdf
Quality Assurance Contract Expiration Date
 04/30/2027
Installation Instructions
 FL15302_R7_II_MC_AW_PO_FL_Install_Drawings_-_28B26.pdf
 Verified By: National Accreditation & Management Institute
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
15302.5 Aluminum Clad Wood Push-Out Awning Aluminum Clad Wood Push-Out Awning (47_1/4" x 31_1/2")
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +90/-90
 Other: Class CW-PG90; Size Tested 1200mm x 800mm (47 1/4" x 31 1/2") Type-AP; Water Test Press 730Pa (15.0psf); CDN. Air Infil/Exfil. Level=A3. Glass meets the requirements of ASTM E1300.
Certification Agency Certificate
 FL15302_R7_C_CAC_NI010955.01-R3.pdf
Quality Assurance Contract Expiration Date
 12/31/2026
Installation Instructions
 FL15302_R7_II_MC_AW_PO_FL_Install_Drawings_-_28B26.pdf
 Verified By: National Accreditation & Management Institute
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
15302.6 Aluminum Clad Wood Push-Out Awning Aluminum Clad Wood Push-Out Awning (63" x 39_3/8")
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +50/-50
 Other: Class CW-PG50; Size Tested 1600mm x 1000mm (63" x 39 3/8") Type-AP; Water Test Press 730Pa (15.0psf); CDN. Air Infil/Exfil. Level=A3. Glass meets the requirements of ASTM E1300.
Certification Agency Certificate
 FL15302_R7_C_CAC_NI010955-R3.pdf
Quality Assurance Contract Expiration Date
 12/31/2026
Installation Instructions
 FL15302_R7_II_MC_AW_PO_FL_Install_Drawings_-_28B26.pdf
 Verified By: National Accreditation & Management Institute
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex