Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-60 Other: Refer to DWG FC-6 thru FC-8 for Max. design pressures for each door width & slat gauge thickness. Max door height is 30 ft. Slat material is available in galvanized or stainless steel. Mounting to steel jambs or concrete |
Installation Instructions FL14017_R1_II_RediStormInstallationInstr.STAMPED.pdf Verified By: Felice P DeGiovanni 55071 Created by Independent Third Party: Yes Evaluation Reports FL14017_R1_AE_DWG 1 thru 8.pdf FL14017_R1_AE_FL14017_R1_AE_FLPRODUCTREPORT-R1.pdf Created by Independent Third Party: Yes |