Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL14016-R7
Application Type Revision
Code Version 2026
Application Status Applied For
 
Comments
Archived
 
Product Manufacturer Central States Manufacturing, Inc.
Address/Phone/Email 302 Jane Place
Lowell, AR 72745
(479) 557-0898
jorge.lopez@centralstatesco.com
 
Authorized Signature Jorge Lopez
jorge.lopez@centralstatesco.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Structural Components
Subcategory Roof Deck
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Bala Sockalingam
Florida License PE-62240
Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity
Quality Assurance Contract Expiration Date 12/31/2029
Validated By Yoosef Lavi, P.E.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL14016_R7_COI_CertificateIndependence.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM E15922017
FM 44702022
FM 44711992
UL 5802006
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 10/18/2026
Date Validated
 
Summary of Products
FL # Model, Number or Name Description
14016.1 Central Seam Plus Min. 24 ga., max. 24" wide standing seam roof panel with or without wind clamps over open supports
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-176.5
 Other: Without Wind Clamp, uplift load of 38.0 psf at clip spacing of 60" o.c. and 98.5 psf at clip spacing of 12" o.c. With Wind Clamps, uplift load of 56.8 psf at clip spacing of 60" o.c. and 176.5 psf at clip spacing of 12" o.c.
Installation Instructions
 FL14016_R7_II_EvaluationReportC3074_1.pdf
 Verified By: Bala Sockalingam, P.E. 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL14016_R7_AE_EvaluationReportC3074_1.pdf
 Created by Independent Third Party: Yes
14016.2 Central Span Max 16" wide, min 24 ga. Standing Seam Panel over open supports
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-235
 Other: Maximum uplift load of 235 psf at support spacing of 24" o.c. with MPS 1200 Series clips and QuadLok seam
Installation Instructions
 FL14016_R7_II_EvaluationReportC3074_2.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL14016_R7_AE_EvaluationReportC3074_2.pdf
 Created by Independent Third Party: Yes
14016.3 Central-Loc Min. 24 ga., max. 24" wide snap lock roof panel over open supports
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-52.5
 Other: Uplift load of 52.5 psf at clip spacing of 60" o.c.
Installation Instructions
 FL14016_R7_II_EvaluationReportC3074_3.pdf
 Verified By: Bala Sockalingam, P.E. 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL14016_R7_AE_EvaluationReportC3074_3.pdf
 Created by Independent Third Party: Yes
14016.4 M-Loc Min. 26 ga., 36" wide, through fastened panel over open steel supports
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-114.7
 Other: Uplift load of 43.2 psf at fastener spacing of 60" o.c. and 114.7 psf at fastener spacing of 24" o.c
Installation Instructions
 FL14016_R7_II_EvaluationReportC3074_4.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL14016_R7_AE_EvaluationReportC3074_4.pdf
 Created by Independent Third Party: Yes
14016.5 R-Loc Min. 26 ga., 36" wide, through fastened panel over open steel supports
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-112.7
 Other: Uplift load of 44.2 psf at fastener spacing of 60" o.c. and 112.7 psf at fastener spacing of 24" o.c.
Installation Instructions
 FL14016_R7_II_EvaluationReportC3074_5.pdf
 Verified By: Bala Sockalingam, P.E. 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL14016_R7_AE_EvaluationReportC3074_5.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex