| 23205.1 |
.1 Roll Up Shutter/Windborne Debri Region RLL-3, A-200-H, A-150-H Slat/NHVHZ |
Extruded aluminum slats interlocked together thru knuckles and retained by tracks to provide hurricane protection. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +varies/-varies Other: Large Missile Impact Resistant, Missile Level "D" wind zones 1, 2, 3, 4. (basic protection only). A.S.D. Pressure rating of +/-25 psf at 5'-11" span w/ Type 2 slat or 6'-0" span w/ Type 3 slat or 4'-5" span w/ Type 4 slat. See remaining pressures and spans on Sheet 10 of installation drawings. |
Installation Instructions FL23205_R3_II_PED Drwg 26-072 Rollac.pdf Verified By: Walter A. Tillit Jr., P.E. PE-44167 Created by Independent Third Party: Yes Evaluation Reports FL23205_R3_AE_PER Drwg 26-072 Rollac.pdf Created by Independent Third Party: Yes |
|
|
| 23205.2 |
.2 RLL 55-X Slat End Retention Roll Up Shutter/NHVHZ |
Extruded aluminum slats interlocked together thru knuckles and retained by tracks to provide hurricane protection. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +varies/-varies Other: Impact Resistant Large missile level "D" wind zones 1, 2, 3 and 4 (basic protection only). A.S.D. Pressure rating: +/-30 psf at 19'-8" span and +/-160 psf at 6'-9" span with 3/16" slip. See sheets 10 and 18 of installation drawing for additional pressures and spans. |
Installation Instructions FL23205_R3_II_PED Drwg 26-073 Rollac.pdf Verified By: Walter A. Tillit Jr., PE PE44167 Created by Independent Third Party: Yes Evaluation Reports FL23205_R3_AE_PER Drwg 26-073 Rollac.pdf Created by Independent Third Party: Yes |
|
|
| 23205.3 |
.3 RLL 55-X Slat Non-End Retention Roll Up Shutter/NHVHZ |
Extruded aluminum slats interlocked together thru knuckles and retained by tracks to provide hurricane protection. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +varies/-varies Other: Impact Resistant Large missile level "D" wind zones 1, 2, 3 and 4 (basic protection only). A.S.D. Pressure rating: +/- 25 psf at 7'-0" span for single unit and +/- 72 psf at 5'-2.5" span. See sheets 10 and 11 of installation drawing for additional pressures and spans. |
Installation Instructions FL23205_R3_II_PED Drwg 26-074 Rollac.pdf Verified By: Walter A. Tillit Jr., PE PE44167 Created by Independent Third Party: Yes Evaluation Reports FL23205_R3_AE_PER Drwg 26-074 Rollac.pdf Created by Independent Third Party: Yes |