| 9093.1 |
PBR |
26 Ga. PBR Roof Panel, 36" Wide over Open Framing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +60.0 PSF/-46.8 PSF Other: -46.8 psf @ 5'-0" o.c. fastener spacing. +60.0 psf @ 5'-0" o.c. fastener spacing. Install per manufacturers details and in compliance w/Current FBC. Not for use in HVHZ Zones. |
Installation Instructions FL9093_R6_II_26 Ga. PBR Panel Structural Roof.pdf Verified By: Johnathan E. Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL9093_R6_AE_26 Ga. PBR Panel Structural Roof.pdf Created by Independent Third Party: Yes |
|
|
| 9093.2 |
PBU |
26 Ga. PBU Roof Panel, 36" wide over open framing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +60.0 Psf/-49.4 PSf Other: -49.4 psf @ 5'-0" o.c. fastener spacing. +60.0 psf @ 5'-0" o.c. fastener spacing. Install per manufacturers details and in compliance w/ CURRENT FBC . Not for use in HVHZ Zones. |
Installation Instructions FL9093_R6_II_26 Ga. PBU Panel Structural Roof.pdf Verified By: Johnathan E. Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL9093_R6_AE_26 Ga. PBU Panel Structural Roof.pdf Created by Independent Third Party: Yes |