Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL16083-R4
Application Type Revision
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer ATAS International, Inc.
Address/Phone/Email 6612 Snowdrift Road
Allentown, PA 18106
(610) 395-8445   Ext 223
jbush@atas.com
 
Authorized Signature james bush
jbush@atas.com
 
Technical Representative James E. Bush
Address/Phone/Email ATAS International, Inc.
6612 Snowdrift Road
Allentown, PA 18106
jbush@atas.com
 
Quality Assurance Representative James Bush
Address/Phone/Email 6612 Snowdrift Road
Allentown, PA 18106
jbush@atas.com
 
Category Panel Walls
Subcategory Soffits
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Russel N. Emery
Florida License PE-71060
Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity
Quality Assurance Contract Expiration Date 12/31/2026
Validated By Steven M. Urich, PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL16083_R4_COI_Certificate of Independence - Opaline 16083.pdf
FL16083_R4_COI_Certificate of Independence - Wind-Lok 16083.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
AAMA 14022009
ASTM E3302014
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 02/19/2024
Date Validated 02/19/2024
Date Pending FBC Approval 02/22/2024
Date Approved 04/16/2024
 
Summary of Products
FL # Model, Number or Name Description
16083.1 OPALINE and MPS120 OPWO45, OPWO65, OPFO40, OPFO60, OPMO45, MPS120/MPV120
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +107/-127
 Other: For all Opaline series panels negative pressure allowed of 134psf
Installation Instructions
 FL16083_R4_II_(FMTECS-08) MP Multi-Purpose Florida Building Code_01_12-11-23 (1).pdf
 FL16083_R4_II_(FMTECS-09) OP Opaline Florida Building Code_01_12-11-23 (1).pdf
 Verified By: Christopher S. Bleschsmidt P.E. 61272
 Created by Independent Third Party: Yes
Evaluation Reports
 FL16083_R4_AE_ATAS FBC Product Approval Document - Opaline.pdf
 FL16083_R4_AE_ATAS FBC Product Approval Document - Wind-Lok.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex