Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL41057-R2
Application Type Revision
Code Version 2023
Application Status Approved
  *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
 
Comments
Archived
 
Product Manufacturer Marvin
Address/Phone/Email Hwy 11 West
Warroad, MN 56763
(218) 386-1430   Ext 2143
cherylf@marvin.com
 
Authorized Signature Cheryl Hill
cherylf@marvin.com
 
Technical Representative Cheryl Fish
Address/Phone/Email PO Box 100
Warroad, MN 56763
(800) 346-5044   Ext 2143
cherylf@marvin.com
 
Quality Assurance Representative
Address/Phone/Email
 
Category Exterior Doors
Subcategory Swinging Exterior Door Assemblies
 
Compliance Method Certification Mark or Listing
 
Certification Agency Window and Door Manufacturer Association
Validated By Window and Door Manufacturers Association
 
 
 
Referenced Standard and Year (of Standard)
StandardYear
AAMA/WDMA/CSA 101/I.S.2/A4402011
AAMA/WDMA/CSA 101/I.S.2/A4402017
ASTM E 188613a
ASTM E19962017
 
Equivalence of Product Standards
Certified By

 
 
 
 
Product Approval Method Method 1 Option A
 
Date Submitted 11/11/2024
Date Validated 11/13/2024
Date Pending FBC Approval
Date Approved 11/13/2024
Date Revised 10/07/2026
 
Summary of Products
FL # Model, Number or Name Description
41057.1 UOD 2.25 IZ3 CN6080 XX Ultimate Outswing Door 2.25 IZ3 CN6080 XX
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +65/-65
 Other: Max Size: 72 5/8 x 98" Max Panel Width: 35.063" Wind Zone 3 Missile Level D. Glass makeup; insulating glass consisting of a 4.7 mm (3/16") tempered exterior lite, and a 8.6mm laminated interior lite. The laminated interior lite was comprised of two, 3.0 mm annealed sheets with a 2.2 mm (.090") SGP interlayer. Glass complies with ASTM E1300. Hardware is multipoint lock
Certification Agency Certificate
 FL41057_R2_C_CAC_UOD 2.25 IZ3 6080 XX 1164.25.26.27.pdf
Quality Assurance Contract Expiration Date
 08/31/2031
Installation Instructions
 FL41057_R2_II_132923 OPER.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
41057.2 UOD 2.25 IZ3 3080 and UOFD 2.25 G2 IZ3 3080 O Ultimate Outswing Door 2.25 IZ3 3080 and Ultimate Outswing French Door 2.25 G2 IZ3 3080 O
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +65/-65
 Other: Max Size: 37 7/16 x 98" Max Panel Width: 35.063" Wind Zone 3 Missile Level D. Glass makeup; insulating glass consisting of a 3.9 mm (5/32") tempered exterior lite, and a 8.6 mm laminated interior lite. The laminated interior lite was comprised of two, 3.1 mm annealed sheets with a 2.3 mm (.090") PVB interlayer. Glass complies with ASTM E1300.
Certification Agency Certificate
 FL41057_R2_C_CAC_CCL 1161.20.21.22.pdf
Quality Assurance Contract Expiration Date
 12/12/2033
Installation Instructions
 FL41057_R2_II_00139990 UID2.25 O INSTALLATION.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
41057.3 UOD 2.25 IZ3 STAT CN3680 Ultimate Outswing Door 2.25 IZ3 Stationary CN3680
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +65/-65
 Other: Max Size: 43 7/16 x 98" Max Panel Width: 41.063" Wind Zone 3 Missile Level D. Glass makeup; insulating glass consisting of a 4.7 mm (3/16") tempered exterior lite, and a 8.6 mm laminated interior lite. The laminated interior lite was comprised of two, 3.0 mm annealed sheets with a 2.2 mm (.090") SGP interlayer. Glass complies with ASTM E1300.
Certification Agency Certificate
 FL41057_R2_C_CAC_UOD 2.25 IZ3 STAT 3680 1161.14.15.16.pdf
Quality Assurance Contract Expiration Date
 08/18/2031
Installation Instructions
 FL41057_R2_II_132882 STAT.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
41057.4 UOD TR 2.25 IZ3 CN8026 Ultimate Outswing Door Transom 2.25 IZ3 CN8026
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +65/-65
 Other: Max frame size 96-5/8" x 30". Max sash width is 94-1/4". Wind zone 3 , Missile Level D. Glass is 3/4" IG consisting of 4.7mm (3/16") annealed exterior lite and 6.9mm laminated interior lite made up of 2 panes of 2.2 annealed with .090" SGP interlayer. Glass complies with ASTM E1300
Certification Agency Certificate
 FL41057_R2_C_CAC_1162.11.12.13.pdf
Quality Assurance Contract Expiration Date
 08/16/2031
Installation Instructions
 FL41057_R2_II_132946 UOD TRANS.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
41057.5 UOFD 2.25 G2 IZ3 CN60100 XX Ultimate Outswing French Door 2.25 G2 IZ3 CN60100 XX
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +65/-65
 Other: Max Size: 72 5/8" x 122" Max Panel Width: 35.063" Wind Zone 3 Missile Level D. Glass makeup; insulating glass consisting of a 5.7 mm (1/4") tempered exterior lite, and a 10.1mm laminated interior lite. The laminated interior lite was comprised of two, 3.9 mm annealed sheets with a 2.2 mm (.090") SGP interlayer. Glass complies with ASTM E1300. Hardware; Multipoint lock
Certification Agency Certificate
 FL41057_R2_C_CAC_UOFD 2.25 G2 IZ3 60100 XX 1164.31.32.33.pdf
Quality Assurance Contract Expiration Date
 09/02/2031
Installation Instructions
 FL41057_R2_II_132923 OPER.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
41057.6 UOFD 2.25 G2 IZ3 CN6080 XX Ultimate Outswing French Door 2.25 G2 IZ3 CN6080 XX
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +65/-65
 Other: Max Size: 72 5/8 x 98" Max Panel Width: 35.063" Wind Zone 3 Missile Level D. Glass makeup; insulating glass consisting of a 3.9 mm (5/32") tempered exterior lite, and a 8.6mm laminated interior lite. The laminated interior lite was comprised of two, 3.1 mm annealed sheets with a 2.3 mm (.090") PVB interlayer. Glass complies with ASTM E1300. Hardware is multipoint lock
Certification Agency Certificate
 FL41057_R2_C_CAC_CCL 1164.38.39.40.pdf
Quality Assurance Contract Expiration Date
 02/19/2034
Installation Instructions
 FL41057_R2_II_00139988 UOFD2.25G2 IZ3 XX INSTALLATION.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
41057.7 UOFD 2.25 G2 IZ3 CN7080 XX Ultimate Outswing French Door 2.25 G2 IZ3 CN7080 XX
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +65/-65
 Other: Max Size: 84 5/8 x 98" Max Panel Width: 41.063" Wind Zone 3 Missile Level D. Glass makeup; insulating glass consisting of a 4.7 mm (3/16") tempered exterior lite, and a 8.6 mm laminated interior lite. The laminated interior lite was comprised of two, 3.0 mm annealed sheets with a 2.2 mm (.090") SGP interlayer. Glass complies with ASTM E1300.
Certification Agency Certificate
 FL41057_R2_C_CAC_UOFD 2.25 G2 IZ3 7080 XX 1164.28.29.30.pdf
Quality Assurance Contract Expiration Date
 09/15/2031
Installation Instructions
 FL41057_R2_II_132923 OPER.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
41057.8 UOFD 2.25 G2 IZ3 STAT CN36100 Ultimate Outswing French Door 2.25 G2 IZ3 Stationary CN36100
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +65/-65
 Other: Max Size: 43 7/16 x 122" Max Panel Width: 41.063" Wind Zone 3 Missile Level D. Glass makeup; insulating glass consisting of a 5.7 mm (1/4") tempered exterior lite, and a 10.1mm laminated interior lite. The laminated interior lite was comprised of two, 3.9 mm annealed sheets with a 2.2 mm (.090") SGP interlayer. Glass complies with ASTM E1300.
Certification Agency Certificate
 FL41057_R2_C_CAC_UOFD 2.25 G2 IZ3 STAT 36100 1161.17.18.19.pdf
Quality Assurance Contract Expiration Date
 08/18/2031
Installation Instructions
 FL41057_R2_II_132882 STAT.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
41057.9 UOFD 2.25 SL G2 IZ3 CN36100 Ultimate Outswing French Door 2.25 Sidelite G2 IZ3 CN36100
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +65/-65
 Other: Max Size: 43 7/16 x 122" Max Panel Width: 41.063" Wind Zone 3 Missile Level D. Glass makeup; insulating glass consisting of a 5.7 mm (1/4") tempered exterior lite, and a 10.1mm laminated interior lite. The laminated interior lite was comprised of two, 3.9 mm annealed sheets with a 2.2 mm (.090") SGP interlayer. Glass complies with ASTM E1300.
Certification Agency Certificate
 FL41057_R2_C_CAC_UOFD 2.25 SL G2 IZ3 36100 1161.17.18.19.pdf
Quality Assurance Contract Expiration Date
 08/18/2031
Installation Instructions
 FL41057_R2_II_132882 STAT.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
41057.10 UOFD 2.25 SL G2 IZ3 CN3680 Ultimate Outswing French Door 2.25 Sidelite G2 IZ3 CN3680
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +65/-65
 Other: Max Size: 43 7/16 x 98" Max Panel Width: 41.063" Wind Zone 3 Missile Level D. Glass makeup; insulating glass consisting of a 4.7 mm (3/16") tempered exterior lite, and a 8.6 mm laminated interior lite. The laminated interior lite was comprised of two, 3.0 mm annealed sheets with a 2.2 mm (.090") SGP interlayer. Glass complies with ASTM E1300.
Certification Agency Certificate
 FL41057_R2_C_CAC_UOFD 2.25 SL G2 IZ3 3680 1161.14.15.16.pdf
Quality Assurance Contract Expiration Date
 08/18/2031
Installation Instructions
 FL41057_R2_II_132882 STAT.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
41057.11 UOFD TR G2 2.25 IZ3 CN8026 Ultimate Outswing French Door Transom 2.25 G2 IZ3 CN8026
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +65/-65
 Other: Max frame size 96-5/8" x 30". Max sash width is 94-1/4". Wind zone 3 , Missile Level D. Glass is 3/4" IG consisting of 4.7mm (3/16") annealed exterior lite and 6.9mm laminated interior lite made up of 2 panes of 2.2 annealed with .090" SGP interlayer. Glass complies with ASTM E1300
Certification Agency Certificate
 FL41057_R2_C_CAC_1162.11.12.13.pdf
Quality Assurance Contract Expiration Date
 08/16/2031
Installation Instructions
 FL41057_R2_II_132946 UOD TRANS.pdf
 Verified By: Window and Door Manufacturer Association
 Created by Independent Third Party: 
Evaluation Reports
 Created by Independent Third Party: 
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex