| 34566.1 |
BOSS FIRM LOC |
Max 16" wide, nom 0.032" thick (min.) aluminum standing seam panel over min 15/32" thick plywood deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-138.5 Other: Uplift load of 65.8 psf at clip spacing of 24" o.c. and 138.5 psf at clip spacing of 6" o.c. For installation in areas within 3000 ft. of a saltwater coastline, clips and fasteners are corrosion resistant as per FBC 2026 Section 1711. |
Installation Instructions FL34566_R2_II_Aluminum Boss Firm Loc .pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL34566_R2_TR_Aluminum Boss Firm Loc .pdf |
|
|
| 34566.2 |
BOSS FIRM LOC |
Max 16" wide, 24 ga. standing seam panel over min 15/32" thick plywood deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-123 Other: Uplift load of 73.6 psf at clip spacing of 24" o.c. and 123.0 psf at clip spacing of 6" o.c. For installation in areas within 3000 ft. of a saltwater coastline, clips and fasteners are corrosion resistant as per FBC 2026 Section 1711. |
Installation Instructions FL34566_R2_II_Steel Boss Firm Loc .pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL34566_R2_TR_Steel Boss Firm Loc .pdf |
|
|
| 34566.3 |
BOSS HARDY LOC |
Max 17" wide, nom 0.040" thick (min.) aluminum standing seam panel over metal deck. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-143.8 Other: Uplift load of 108.7 psf at clip spacing of 24" o.c. and 143.8 psf at clip spacing of 12" o.c. For installation in areas within 3000 ft. of a saltwater coastline, clips and fasteners are corrosion resistant as per FBC 2026 Section 1711. |
Installation Instructions FL34566_R2_II_Aluminum Boss Hardy Loc.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL34566_R2_TR_Aluminum Boss Hardy Loc.pdf |
|
|
| 34566.4 |
BOSS RIB |
Min 26 ga., 36" wide through fastened panel over min 15/32" thick plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-78.5 Other: Uplift load of 58.3 psf at fastener spacing of 24" o.c. and 78.5 psf at fastener spacing of 12" o.c. For installation in areas within 3000 ft. of a saltwater coastline, fasteners are corrosion resistant as per FBC 2026 Section 1711. |
Installation Instructions FL34566_R2_II_Boss Rib.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL34566_R2_TR_Boss Rib.pdf |
|
|
| 34566.5 |
BOSS WAVE |
Min 26 ga. through fastened panel with coverage width of 21" over min 15/32" thick plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-104.8 Other: Uplift load of 81.4 psf at fastener spacing of 24" o.c. and 104.8 psf at fastener spacing of 12" o.c. For installation in areas within 3000 ft. of a saltwater coastline, fasteners are corrosion resistant as per FBC 2026 Section 1711. |
Installation Instructions FL34566_R2_II_Boss Wave.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL34566_R2_TR_Boss Wave.pdf |