FL # FL34566-R1
Application Type Revision
Code Version 2023
Application Status Approved
  *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
 
Comments
Archived
 
Product Manufacturer Boss Metals
Address/Phone/Email 1750 Frankford Ave
Panama City, FL 32405
(850) 481-5629
david@bossmetals.com
 
Authorized Signature David Bowers
david@bossmetals.com
 
Technical Representative David Bowers
Address/Phone/Email 750 Frankford Ave
Panama City, FL 32405
(850) 481-5629
david@bossmetals.com
 
Quality Assurance Representative
Address/Phone/Email
 
Category Roofing
Subcategory Metal Roofing
 
Compliance Method Test Report
 
Testing Lab Farabaugh Engineering and Testing, LLC
Quality Assurance Entity Farabaugh Engineering and Testing, LLC
Quality Assurance Contract Expiration Date 12/31/2026
Validated By Bala Sockalingam, P.E.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL34566_R1_COI_CertificateIndependence.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
UL 18972015
UL 5802006
 
Equivalence of Product Standards
Certified By

Approved Testing Lab
FL34566_R1_Equiv_BossT236-20EQ.pdf
FL34566_R1_Equiv_BossT238-20EQ.pdf
FL34566_R1_Equiv_BossT239-20EQ.pdf
FL34566_R1_Equiv_BossT240-20EQ.pdf
FL34566_R1_Equiv_BossT242-20EQ.pdf
 
 
 
 
Product Approval Method Method 1 Option B
 
Date Submitted 08/26/2023
Date Validated 09/01/2023
Date Pending FBC Approval
Date Approved 09/10/2023
Date Revised 10/17/2026
 
Summary of Products
FL # Model, Number or Name Description
34566.1 BOSS FIRM LOC Max 16" wide, nom 0.032" thick (min.) aluminum standing seam panel over min 15/32" thick plywood deck
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-138.5
 Other: Uplift load of 65.8 psf at clip spacing of 24" o.c. and 138.5 psf at clip spacing of 6" o.c.
Installation Instructions
 FL34566_R1_II_Aluminum Boss Firm Loc .pdf
 Verified By: Farabaugh Engineering and Testing, LLC
Test Reports
 FL34566_R1_TR_Aluminum Boss Firm Loc .pdf
34566.2 BOSS FIRM LOC Max 16" wide, 24 ga. standing seam panel over min 15/32" thick plywood deck
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-123
 Other: Uplift load of 73.6 psf at clip spacing of 24" o.c. and 123.0 psf at clip spacing of 6" o.c.
Installation Instructions
 FL34566_R1_II_Steel Boss Firm Loc .pdf
 Verified By: Farabaugh Engineering and Testing, LLC
Test Reports
 FL34566_R1_TR_Steel Boss Firm Loc .pdf
34566.3 BOSS HARDY LOC Max 17" wide, nom 0.040" thick (min.) aluminum standing seam panel over metal deck.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-143.8
 Other: Uplift load of 108.7 psf at clip spacing of 24" o.c. and 143.8 psf at clip spacing of 12" o.c.
Installation Instructions
 FL34566_R1_II_Aluminum Boss Hardy Loc.pdf
 Verified By: Farabaugh Engineering and Testing, LLC
Test Reports
 FL34566_R1_TR_Aluminum Boss Hardy Loc.pdf
34566.4 BOSS RIB Min 26 ga., 36" wide through fastened panel over min 15/32" thick plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-78.5
 Other: Uplift load of 58.3 psf at fastener spacing of 24" o.c. and 78.5 psf at fastener spacing of 12" o.c.
Installation Instructions
 FL34566_R1_II_Boss Rib.pdf
 Verified By: Farabaugh Engineering and Testing, LLC
Test Reports
 FL34566_R1_TR_Boss Rib.pdf
34566.5 BOSS WAVE Min 26 ga. through fastened panel with coverage width of 21" over min 15/32" thick plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-104.8
 Other: Uplift load of 81.4 psf at fastener spacing of 24" o.c. and 104.8 psf at fastener spacing of 12" o.c.
Installation Instructions
 FL34566_R1_II_Boss Wave.pdf
 Verified By: Farabaugh Engineering and Testing, LLC
Test Reports
 FL34566_R1_TR_Boss Wave.pdf
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex