| 17444.1 |
Series 2050 |
Greenhouse Window - Impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: |
Certification Agency Certificate FL17444_R9_C_CAC_10-118_C2R0.pdf FL17444_R9_C_CAC_10-201_C2R0.pdf Quality Assurance Contract Expiration Date 10/09/2024 Installation Instructions FL17444_R9_II_ACE0003_Rev0_Ventana_GardenWindow_Impact_ss.pdf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL17444_R9_AE_PER-ACE-1007_Rev2_Ventana_2050-2051GardenWindow_ss.pdf Created by Independent Third Party: Yes |
|
|
| 17444.2 |
Series 2050/2051 |
Garden Window - Non-Impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: |
Certification Agency Certificate FL17444_R9_C_CAC_10-127_C1R0.pdf Quality Assurance Contract Expiration Date 08/14/2024 Installation Instructions FL17444_R9_II_ACE0001_Rev0_Ventana_GardenWindow_NI_ss.pdf Verified By: Robert J Amoruso, P.E. FL PE License 49752 Created by Independent Third Party: Yes Evaluation Reports FL17444_R9_AE_PER-ACE-1007_Rev2_Ventana_2050-2051GardenWindow_ss.pdf Created by Independent Third Party: Yes |
|
|
| 17444.3 |
Series 3000/3100 |
Casement Window - New Construction |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +55/-55 Other: |
Certification Agency Certificate FL17444_R9_C_CAC_10-128_R1.pdf Quality Assurance Contract Expiration Date 05/24/2025 Installation Instructions FL17444_R9_II_ACE0002_Rev0_Ventana_3000-3001-Casement_NI_ss.pdf Verified By: Robert J Amoruso, P.E. FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL17444_R9_AE_PER-ACE-1011_Rev2_Ventana_3000-3100CasementWindowNI_ss.pdf Created by Independent Third Party: Yes |
|
|
| 17444.4 |
Series 3000/3100 |
Casement Window - Replacement/Retrofit |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +60/-60 Other: |
Certification Agency Certificate FL17444_R9_C_CAC_10-129_R1.pdf Quality Assurance Contract Expiration Date 05/24/2025 Installation Instructions FL17444_R9_II_ACE0002_Rev0_Ventana_3000-3001-Casement_NI_ss.pdf Verified By: Robert J Amoruso, P.E. FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL17444_R9_AE_PER-ACE-1011_Rev2_Ventana_3000-3100CasementWindowNI_ss.pdf Created by Independent Third Party: Yes |