| 17419.1 |
Insulated Door |
CP0001/CP0651 Slat |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +120/-120 Other: Refer to DWG ES-16-137 for maximum design pressure for each door width. The maximum height for all doors is 30 ft. Maximum design pressure is 120 psf. Impact resistant for 50 FPS missile impact speed. Mounting to steel jamb, concrete jamb, or filled CMU jamb. Slat material is available in galvanized or stainless steel. |
Installation Instructions FL17419_R10_II_10-476 Installation Instructions, Service Door_S_S (8-20-26).pdf Verified By: Shawn Patrick Kelley FL 58299 Created by Independent Third Party: No Evaluation Reports FL17419_R10_AE_16-137 FL Approval - CP1, 50fps CIW_S_S (8-19-26).pdf FL17419_R10_AE_FBC 2023 Code Compliance (CIW; 134-138, 140)_S_S (8-19-26).pdf Created by Independent Third Party: Yes |
|
|
| 17419.2 |
Insulated Door |
CP0001/CP0651 Slat |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +120/-120 Other: Refer to DWG ES-16-138 for maximum design pressure for each door width. The maximum height for all doors is 30 ft. Maximum design pressure is 120 psf. Impact resistant for 80 FPS missile impact speed. Mounting to steel jamb, concrete jamb, or filled CMU jamb. Slat material is available in galvanized or stainless steel. |
Installation Instructions FL17419_R10_II_10-476 Installation Instructions, Service Door_S_S (8-20-26).pdf Verified By: Shawn Patrick Kelley FL 58299 Created by Independent Third Party: No Evaluation Reports FL17419_R10_AE_16-138 FL Approval - CP1, 80fps CIW_S_S (8-19-26).pdf FL17419_R10_AE_FBC 2023 Code Compliance (CIW; 134-138, 140)_S_S (8-19-26).pdf Created by Independent Third Party: Yes |
|
|
| 17419.3 |
Insulated Door |
CP0001/CP0651 Slat |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +120/-120 Other: Refer to DWG ES-16-140 for maximum design pressure for each door width. The maximum height for all doors is 30 ft. Maximum design pressure is 120 psf. Mounting to steel jamb, concrete jamb, or filled CMU jamb. Slat material is available in galvanized or stainless steel. |
Installation Instructions FL17419_R10_II_10-476 Installation Instructions, Service Door_S_S (8-20-26).pdf Verified By: Shawn Patrick Kelley FL 58299 Created by Independent Third Party: No Evaluation Reports FL17419_R10_AE_16-140 FL Approval - CP1, Non-Impact CIW_S_S (8-19-26).pdf FL17419_R10_AE_FBC 2023 Code Compliance (CIW; 134-138, 140)_S_S (8-19-26).pdf Created by Independent Third Party: Yes |
|
|
| 17419.4 |
Non-Insulated Door |
CP0020 Slat |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +100/-100 Other: Refer to DWG ES-16-134 for maximum design pressure for each door width. The maximum height for all doors is 30 ft. Maximum design pressure is 100 psf. Impact resistant for 50 FPS missile impact speed. Mounting to steel jamb, concrete jamb, or filled CMU jamb. Slat material is available in galvanized or stainless steel. |
Installation Instructions FL17419_R10_II_10-476 Installation Instructions, Service Door_S_S (8-20-26).pdf Verified By: Shawn Patrick Kelley FL 58299 Created by Independent Third Party: No Evaluation Reports FL17419_R10_AE_16-134 FL Approval - C20, 50fps_SandS (12-8-25).pdf FL17419_R10_AE_FBC 2023 Code Compliance (CIW_ 134-138, 140)_SandS (12-15-25).pdf Created by Independent Third Party: Yes |
|
|
| 17419.5 |
Non-Insulated Door |
CP0020 Slat |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +100/-100 Other: Refer to DWG ES-16-135 for maximum design pressure for each door width. The maximum height for all doors is 30 ft. Maximum design pressure is 100 psf. Impact resistant for 80 FPS missile impact speed. Mounting to steel jamb, concrete jamb, or filled CMU jamb. Slat material is available in galvanized or stainless steel. |
Installation Instructions FL17419_R10_II_10-476 Installation Instructions, Service Door_S_S (8-20-26).pdf Verified By: Shawn Patrick Kelley FL 58299 Created by Independent Third Party: No Evaluation Reports FL17419_R10_AE_16-135 FL Approval - C20, 80fps_SandS (12-11-25).pdf FL17419_R10_AE_FBC 2023 Code Compliance (CIW_ 134-138, 140)_SandS (12-15-25).pdf Created by Independent Third Party: Yes |
|
|
| 17419.6 |
Non-Insulated Door |
CP0020 Slat |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +100/-100 Other: Refer to DWG ES-16-136 for maximum design pressure for each door width. The maximum height for all doors is 30 ft. Maximum design pressure is 100 psf. Mounting to steel jamb, concrete jamb, or filled CMU jamb. Slat material is available in galvanized or stainless steel. |
Installation Instructions FL17419_R10_II_10-476 Installation Instructions, Service Door_S_S (8-20-26).pdf Verified By: Shawn Patrick Kelley FL 58299 Created by Independent Third Party: No Evaluation Reports FL17419_R10_AE_16-136 FL Approval - C20, Non-Impact_SandS (12-11-25).pdf FL17419_R10_AE_FBC 2023 Code Compliance (CIW_ 134-138, 140)_SandS (12-15-25).pdf Created by Independent Third Party: Yes |