FL # FL2211-R3
Application Type Revision
Code Version 2010
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Cookson Company, The
Address/Phone/Email 1901 S. Litchfield Road
Goodyear, AZ 85338
(800) 294-4358   Ext 4694
trevor.errington@cornellcookson.com
 
Authorized Signature Trevor Errington
trevor.errington@cornellcookson.com
 
Technical Representative Michael Ho
Address/Phone/Email 2417 S. 50th Ave.
Phoenix, AZ 85043
(602) 272-4244   Ext 1143
mho@cooksondoor.com
 
Quality Assurance Representative Elizabeth McNeilly
Address/Phone/Email 800 Tulip Drive
Gastonia, NC 28052
(704) 866-9146   Ext 1328
emcneilly@cooksondoor.com
 
Category Exterior Doors
Subcategory Roll-Up Exterior Door Assemblies
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Joseph H. Dixon Jr.
Florida License PE-7768
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 09/04/2015
Validated By Gordon Thomas, P.E.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL2211_R3_COI_Cert of Fin Indep.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
FBC TAS 2011994
FBC TAS 2021994
FBC TAS 2031994
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 04/18/2012
Date Validated 05/02/2012
Date Pending FBC Approval 05/04/2012
Date Approved 06/11/2012
Date Revised 06/18/2015
 
Summary of Products
FL # Model, Number or Name Description
2211.1 TYPE A #5-0.0236, 10'-0" to 18'-0" wide X 30'-0" high #5-0.0296, 10'-0" to 24'-0" wide X 30'-0" high
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +98.3/-98.3
 Other: Doors for various opening sizes are rated for various design wind loads (See the Evaluation Report). The design pressure for the test door width of 14’-4” is +/-52.0 PSF for 0.0236 and +/-52.7 PSF for 0.0296. Not for use in HVHZ.
Installation Instructions
 FL2211_R3_II_Service Door Install Inst 041812.pdf
 FL2211_R3_II_WLCD-001-A-2004 040912_0003.pdf
 Verified By: Joseph H. Dixon, Jr. FL 7768
 Created by Independent Third Party: No
Evaluation Reports
 FL2211_R3_AE_ER-06-0006-R1 041212_0007.pdf
 Created by Independent Third Party: No
2211.2 TYPE A - HVHZ #5-0.0236, up to 14'-4" wide X 30'-0" high #5-0.0296, up to 14'-4" wide X 30'-0" high
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +52.0/-52.0
 Other: The design pressure for the test door width of 14’-4” is +/-52.0 PSF for 0.0236 and +/-52.0 PSF for 0.0296.
Installation Instructions
 FL2211_R3_II_Service Door Install Inst 041812.pdf
 FL2211_R3_II_WLCD-001-A-2004 040912_0003.pdf
 Verified By: Joseph H. Dixon, Jr. FL 7768
 Created by Independent Third Party: No
Evaluation Reports
 FL2211_R3_AE_ER-06-0006-R1 041212_0007.pdf
 Created by Independent Third Party: No
2211.3 Type B #5-0.0296, 10'-0" to 24'-0" wide X 30'-0" high #4-0.0356, 10'-0" to 26'-0" wide X 30'-0" high #45-0.0356/0.0236, 10'-0" to 28'-0" wide X 30'-0" high
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +193.5/-203.5
 Other: Doors for various opening sizes are rated for various design wind loads (See the Evaluation Report). The design pressure for the test door width of 16’-0” is +55.0/-60.0 PSF for #5-0.0296, +55.0/-60.0 PSF for #4-0.0356 and +65.0/-70.0 PSF for #45-0.0356/0.0236. Not for use in HVHZ.
Installation Instructions
 FL2211_R3_II_Service Door Install Inst 041812.pdf
 FL2211_R3_II_WLCD-002-B-2004 040912_0003.pdf
 Verified By: Joseph H. Dixon, Jr. FL 7768
 Created by Independent Third Party: No
Evaluation Reports
 FL2211_R3_AE_ER-06-0006-R1 041212_0007.pdf
 Created by Independent Third Party: No
2211.4 TYPE B - HVHZ #5-0.0296, up to 16'-0" wide X 30'-0" high #4-0.0356, up to 16'-0" wide X 30'-0" high #45-0.0356/0.0236, up to 16'-0" wide X 30'-0" high
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +55.0/-60.0
 Other: The design pressure for the test door width of 16’-0” is +55.0/-60.0 PSF for #5-0.0296, +55.0/-60.0 PSF for #4-0.0356 and +55.0/-60.0 PSF for #45-0.0356/0.0236.
Installation Instructions
 FL2211_R3_II_Service Door Install Inst 041812.pdf
 FL2211_R3_II_WLCD-002-B-2004 040912_0003.pdf
 Verified By: Joseph H. Dixon, Jr. FL 7768
 Created by Independent Third Party: No
Evaluation Reports
 FL2211_R3_AE_ER-06-0006-R1 041212_0007.pdf
 Created by Independent Third Party: No
2211.5 Type C #4-0.0356, 12'-0" to 40'-0" wide X 30'-0" high #45-0.0356/0.0236, 12'-0" to 40'-0" wide X 30'-0" high
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +216.6/-216.6
 Other: Doors for various opening sizes are rated for various design wind loads (See the Evaluation Report). The design pressure for the test door width of 26’-0” is +/-52.0 PSF for #4-0.0356 and +/-54.0 PSF for #45-0.0356/0.0236. Not for use in HVHZ.
Installation Instructions
 FL2211_R3_II_Service Door Install Inst 041812.pdf
 FL2211_R3_II_WLCD-003-C-2004 040912_0003.pdf
 Verified By: Joseph H. Dixon Jr. FL 7768
 Created by Independent Third Party: No
Evaluation Reports
 FL2211_R3_AE_ER-06-0006-R1 041212_0007.pdf
 Created by Independent Third Party: No
2211.6 Type C - HVHZ #4-0.0356, up to 26'-0" wide X 30'-0" high #45-0.0356/0.0236, up to 26'-0" wide X 30'-0" high
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +52.0/-52.0
 Other: The design pressure for the test door width of 26’-0” is +/-52.0 PSF for #4-0.0356 and +/-52.0 PSF for #45-0.0356/0.0236.
Installation Instructions
 FL2211_R3_II_Service Door Install Inst 041812.pdf
 FL2211_R3_II_WLCD-003-C-2004 040912_0003.pdf
 Verified By: Joseph H. Dixon, Jr FL 7768
 Created by Independent Third Party: No
Evaluation Reports
 FL2211_R3_AE_ER-06-0006-R1 041212_0007.pdf
 Created by Independent Third Party: No
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex
SecurityMetrics Credit Card Safe