2211.1 |
TYPE A |
#5-0.0236, 10'-0" to 18'-0" wide X 30'-0" high
#5-0.0296, 10'-0" to 24'-0" wide X 30'-0" high |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +98.3/-98.3 Other: Doors for various opening sizes are rated for various design wind loads (See the Evaluation Report). The design pressure for the test door width of 14’-4” is +/-52.0 PSF for 0.0236 and +/-52.7 PSF for 0.0296.
Not for use in HVHZ. |
Installation Instructions FL2211_R4_II_Service Door Install Inst 041812.pdf FL2211_R4_II_WLCD-001-A-2004 040912_0003.pdf Verified By: Joseph H. Dixon, Jr. FL 7768 Created by Independent Third Party: No Evaluation Reports FL2211_R4_AE_ER-06-0006-R1 041212_0007.pdf Created by Independent Third Party: No |
|
2211.2 |
TYPE A - HVHZ |
#5-0.0236, up to 14'-4" wide X 30'-0" high
#5-0.0296, up to 14'-4" wide X 30'-0" high |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +52.0/-52.0 Other: The design pressure for the test door width of 14’-4” is +/-52.0 PSF for 0.0236 and +/-52.0 PSF for 0.0296. |
Installation Instructions FL2211_R4_II_Service Door Install Inst 041812.pdf FL2211_R4_II_WLCD-001-A-2004 040912_0003.pdf Verified By: Joseph H. Dixon, Jr. FL 7768 Created by Independent Third Party: No Evaluation Reports FL2211_R4_AE_ER-06-0006-R1 041212_0007.pdf Created by Independent Third Party: No |
|
2211.3 |
Type B |
#5-0.0296, 10'-0" to 24'-0" wide X 30'-0" high #4-0.0356, 10'-0" to 26'-0" wide X 30'-0" high #45-0.0356/0.0236, 10'-0" to 28'-0" wide X 30'-0" high |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +193.5/-203.5 Other: Doors for various opening sizes are rated for various design wind loads (See the Evaluation Report). The design pressure for the test door width of 16’-0” is +55.0/-60.0 PSF for #5-0.0296, +55.0/-60.0 PSF for #4-0.0356 and +65.0/-70.0 PSF for #45-0.0356/0.0236. Not for use in HVHZ. |
Installation Instructions FL2211_R4_II_Service Door Install Inst 041812.pdf FL2211_R4_II_WLCD-002-B-2004 040912_0003.pdf Verified By: Joseph H. Dixon, Jr. FL 7768 Created by Independent Third Party: No Evaluation Reports FL2211_R4_AE_ER-06-0006-R1 041212_0007.pdf Created by Independent Third Party: No |
|
2211.4 |
TYPE B - HVHZ |
#5-0.0296, up to 16'-0" wide X 30'-0" high #4-0.0356, up to 16'-0" wide X 30'-0" high #45-0.0356/0.0236, up to 16'-0" wide X 30'-0" high |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55.0/-60.0 Other: The design pressure for the test door width of 16’-0” is +55.0/-60.0 PSF for #5-0.0296, +55.0/-60.0 PSF for #4-0.0356 and +55.0/-60.0 PSF for #45-0.0356/0.0236. |
Installation Instructions FL2211_R4_II_Service Door Install Inst 041812.pdf FL2211_R4_II_WLCD-002-B-2004 040912_0003.pdf Verified By: Joseph H. Dixon, Jr. FL 7768 Created by Independent Third Party: No Evaluation Reports FL2211_R4_AE_ER-06-0006-R1 041212_0007.pdf Created by Independent Third Party: No |
|
2211.5 |
Type C |
#4-0.0356, 12'-0" to 40'-0" wide X 30'-0" high #45-0.0356/0.0236, 12'-0" to 40'-0" wide X 30'-0" high |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +216.6/-216.6 Other: Doors for various opening sizes are rated for various design wind loads (See the Evaluation Report). The design pressure for the test door width of 26’-0” is +/-52.0 PSF for #4-0.0356 and +/-54.0 PSF for #45-0.0356/0.0236. Not for use in HVHZ. |
Installation Instructions FL2211_R4_II_Service Door Install Inst 041812.pdf FL2211_R4_II_WLCD-003-C-2004 040912_0003.pdf Verified By: Joseph H. Dixon Jr. FL 7768 Created by Independent Third Party: No Evaluation Reports FL2211_R4_AE_ER-06-0006-R1 041212_0007.pdf Created by Independent Third Party: No |
|
2211.6 |
Type C - HVHZ |
#4-0.0356, up to 26'-0" wide X 30'-0" high #45-0.0356/0.0236, up to 26'-0" wide X 30'-0" high |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +52.0/-52.0 Other: The design pressure for the test door width of 26’-0” is +/-52.0 PSF for #4-0.0356 and +/-52.0 PSF for #45-0.0356/0.0236. |
Installation Instructions FL2211_R4_II_Service Door Install Inst 041812.pdf FL2211_R4_II_WLCD-003-C-2004 040912_0003.pdf Verified By: Joseph H. Dixon, Jr FL 7768 Created by Independent Third Party: No Evaluation Reports FL2211_R4_AE_ER-06-0006-R1 041212_0007.pdf Created by Independent Third Party: No |