| 39385.1 |
Aspect Double Hung (non-Impact) |
Aspect Double Hung Window 40x63 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Overall Size: 40" x 63"
Nail Fin Installation and Thru-Frame Installation Methods |
Certification Agency Certificate FL39385_R2_C_CAC_462-H-002.pdf Quality Assurance Contract Expiration Date 08/09/2034 Installation Instructions FL39385_R2_II_27501.06-1003.pdf Verified By: Michael D. Stremmel, PE PE-65868 Created by Independent Third Party: Yes Evaluation Reports FL39385_R2_AE_27501.06-107-16-F (ProVia LLC Aspect DH).pdf Created by Independent Third Party: Yes |
|
|
| 39385.2 |
Aspect Double Hung (non-Impact) |
Aspect Double Hung Window 44x75 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +45/-45 Other: Overall Size: 44" x 75"
Thru-Frame Installation Method |
Certification Agency Certificate FL39385_R2_C_CAC_462-H-002.pdf Quality Assurance Contract Expiration Date 08/09/2034 Installation Instructions FL39385_R2_II_27501.06-1003.pdf Verified By: Michael D. Stremmel, PE PE-65868 Created by Independent Third Party: Yes Evaluation Reports FL39385_R2_AE_27501.06-107-16-F (ProVia LLC Aspect DH).pdf Created by Independent Third Party: Yes |
|
|
| 39385.3 |
Aspect Double Hung (non-Impact) |
Aspect Double Hung Window 44x75 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Overall Size: 44" x 75"
Nail Fin Installation Method |
Certification Agency Certificate FL39385_R2_C_CAC_462-H-002.pdf Quality Assurance Contract Expiration Date 08/09/2034 Installation Instructions FL39385_R2_II_27501.06-1003.pdf Verified By: Michael D. Stremmel, PE PE-65868 Created by Independent Third Party: Yes Evaluation Reports FL39385_R2_AE_27501.06-107-16-F (ProVia LLC Aspect DH).pdf Created by Independent Third Party: Yes |
|
|
| 39385.4 |
Ecolite Double Hung (non-Impact) |
Ecolite Double Hung Window 36x72 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Overall Size 36" x 72" |
Certification Agency Certificate FL39385_R2_C_CAC_ProVia462CCL Ecolite DH 36x72.pdf Quality Assurance Contract Expiration Date 03/30/2027 Installation Instructions FL39385_R2_II_27501.06-1002.pdf Verified By: Michael D. Stremmel, PE PE-65868 Created by Independent Third Party: Yes Evaluation Reports FL39385_R2_AE_27501.06-107-16-D (ProVia LLC Ecolite DH).pdf Created by Independent Third Party: Yes |
|
|
| 39385.5 |
Ecolite Double Hung (non-Impact) |
Ecolite Double Hung Window 40x62 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Overall Size 40" x 62" |
Certification Agency Certificate FL39385_R2_C_CAC_ProVia462CCL Ecolite DH 40X62.pdf Quality Assurance Contract Expiration Date 03/30/2027 Installation Instructions FL39385_R2_II_27501.06-1002.pdf Verified By: Michael D. Stremmel, PE PE-65868 Created by Independent Third Party: Yes Evaluation Reports FL39385_R2_AE_27501.06-107-16-D (ProVia LLC Ecolite DH).pdf Created by Independent Third Party: Yes |
|
|
| 39385.6 |
Endure Double Hung (non-Impact) |
Endure Double Hung Window 44x75 |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Overall Size 44" x 75" |
Certification Agency Certificate FL39385_R2_C_CAC_ProVia462CCL Endure DH 44x75.pdf Quality Assurance Contract Expiration Date 09/14/2027 Installation Instructions FL39385_R2_II_27501.06-1001.pdf Verified By: Michael D. Stremmel, PE PE-65868 Created by Independent Third Party: Yes Evaluation Reports FL39385_R2_AE_27501.06-107-16-B (ProVia LLC Endure-Aspect DH).pdf Created by Independent Third Party: Yes |