| 10684.1 |
1.5" Mechanical Lock 24 Ga. HVHZ |
1.5" Mechanical Lock 24 Ga. 16" Wide over APA Plywood. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-123.5PSF Other: -59.75 psf @ 24" o.c. Clip Spacing. -123.5 psf @ 6" o.c. Clip Spacing. 15/32" APA plywood for Non HVHZ, Reroof in HVHZ:add additional 15/32"APA plywood, Install per manufacturer details and in compliance w/Current FBC . HVHZ Zones use 19/32" APA plywood for new construction. Panel is non structural.
For use in HVHZ Zones. |
Installation Instructions FL10684_R6_II_FL 10684 2023 REPORTS AND DETAILS BEACH METAL ROOFING SUPPLY LLC.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL10684_R6_AE_FL 10684 2023 REPORTS AND DETAILS BEACH METAL ROOFING SUPPLY LLC.pdf Created by Independent Third Party: Yes |
|
|
| 10684.2 |
1.5" Mechanical Lock 24 Ga. HVHZ (DISCONTINUED) |
1.5" Mechanical Lock 24 Ga. 16" Wide over APA Plywood. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-123.5PSF Other: -59.75 psf @ 24" o.c. Clip Spacing. -123.5 psf @ 6" o.c. Clip Spacing. 15/32" APA plywood for Non HVHZ, Reroof in HVHZ:add additional 15/32"APA plywood, HVHZ 19/32" APA plywood for new construction.For use in HVHZ Zones. Panel is non structural. Install per manufacturer details and in compliance w/ Current FBC
For use in HVHZ Zones. |
Installation Instructions FL10684_R6_II_FL 10684 2023 REPORTS AND DETAILS BEACH METAL ROOFING SUPPLY LLC.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL10684_R6_AE_FL 10684 2023 REPORTS AND DETAILS BEACH METAL ROOFING SUPPLY LLC.pdf Created by Independent Third Party: Yes |
|
|
| 10684.3 |
1.5" Mechanical Lock Aluminum |
1.5" Mechanical Lock 0.032" Aluminum Roof Panel over 19/32" Sealed Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-72.5PSF Other: -72.5 psf. @ 36" o.c. Clip spacing. Install per manufacturers details. Panel is Non structural. Not for use in HVHZ Zones |
Installation Instructions FL10684_R6_II_RFL 10684 2023 REPORTS AND DETAILS BEACH METAL ROOFING SUPPLY LLC.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL10684_R6_AE_RFL 10684 2023 REPORTS AND DETAILS BEACH METAL ROOFING SUPPLY LLC.pdf Created by Independent Third Party: Yes |
|
|
| 10684.4 |
1.5" Nailstrip 24 Ga. HVHZ |
1.5" Nailstrip 24 Ga. 15 1/2" Wide Roof Panel over APA Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116.0PSF Other: -78.5 psf @ 11" o.c. fastener in slot. -116.0 psf @ 6 1/2" o.c. fastener in slot & 12" o.c. fasteners in Pan. Use 15/32" APA plywood for Non HVHZ, Reroofing in HVHZ:use additional 15/32" APA plywood, HVHZ 19/32" APA plywood for new construction. Panel is Non structural. Install per manufacturers details in compliance with Current FBC For use in HVHZ Zones. |
Installation Instructions FL10684_R6_II_FL 10684 2023 REPORTS AND DETAILS BEACH METAL ROOFING SUPPLY LLC.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL10684_R6_AE_FL 10684 2023 REPORTS AND DETAILS BEACH METAL ROOFING SUPPLY LLC.pdf Created by Independent Third Party: Yes |
|
|
| 10684.5 |
1.5" Snap Lock 24 Ga. HVHZ |
1.5" Snap Lock 24 Ga. 16" Wide Roof Panel over APA Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116.0PSF Other: -86.0 psf @ 24" o.c. Clip Spacing. -108.5 psf @ 12" o.c. Clip Spacing. -116.0 psf @ 6" o.c. Clip Spacing. 15/32"APA plywood for Non HVHZ, Reroofing in HVHZ:add additional 15/32" APA plywood, HVHZ 19/32" APA plywood-new construction. Panel is Non structural. Install per manufacturers details in compliance w/FBC, For use in HVHZ Zones. |
Installation Instructions FL10684_R6_II_FL 10684 2023 REPORTS AND DETAILS BEACH METAL ROOFING SUPPLY LLC.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL10684_R6_AE_FL 10684 2023 REPORTS AND DETAILS BEACH METAL ROOFING SUPPLY LLC.pdf Created by Independent Third Party: Yes |
|
|
| 10684.6 |
26 Ga. 5V Crimp Roof Panel |
Min. 26 Ga. 5V Crimp Roof Panel over 15/32" APA Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-156.5 Other: -108.5 psf @ 12" o.c. Clip Spacing. -156.5 psf @ 6" o.c. Clip Spacing. Install per manufacturer's detailS, in compliance w/FBC Panel is Non structural. Not for use in HVHZ Zones. |
Installation Instructions FL10684_R6_II_FL 10684 2023 REPORTS AND DETAILS BEACH METAL ROOFING SUPPLY LLC.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL10684_R6_AE_FL 10684 2023 REPORTS AND DETAILS BEACH METAL ROOFING SUPPLY LLC.pdf Created by Independent Third Party: Yes |
|
|
| 10684.7 |
26Ga. Corrugated Rib |
21.25" panel over 15/32" APA plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/--97.1psf Other: -97.1psf@ 5 1/2"o.c.
-60psf@ 10 3/4"o.c.
Install per manufacturers detail in compliance with Current Building Code FBC. Not for use in HVHZ. |
Installation Instructions FL10684_R6_II_FL 10684 2023 REPORTS AND DETAILS BEACH METAL ROOFING SUPPLY LLC.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL10684_R6_AE_FL 10684 2023 REPORTS AND DETAILS BEACH METAL ROOFING SUPPLY LLC.pdf Created by Independent Third Party: Yes |
|
|
| 10684.8 |
29GA SM Rib |
Min 29GA Rib panel over min. 1x4 No.2 SYP wood purlins over one layer shingles(optional)over min. 7/16" OSB or 15/32" APA plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-157.5psf Other: -45psf@ 24"o.c. and -157.5PSF@ 12"o.c. Panel is Non structural. Install per manufacturer details. In compliance With Current FBC. Not for use in HVHZ. |
Installation Instructions FL10684_R6_II_FL 10684 2023 REPORTS AND DETAILS BEACH METAL ROOFING SUPPLY LLC.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL10684_R6_AE_FL 10684 2023 REPORTS AND DETAILS BEACH METAL ROOFING SUPPLY LLC.pdf Created by Independent Third Party: Yes |