| 10668.1 |
3" x 16" Metal Deck 6' Span |
3" x 16" 20 Ga. Metal Roof Panel for open canopies. 6' Span |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +70 psf/-90 psf Other: Tested in accordance with FBC TAS 202-94 and ASTM E 330-02. Must be installed in accordance with FBC and Manufactures Installation Instructions for roof slopes less than 2:12. Deflection is limited to L/240. |
Installation Instructions FL10668_R5_II_Installation Instructions.pdf Verified By: American Test Lab Inc Test Reports FL10668_R5_TR_Test Report.pdf |
|
|
| 10668.2 |
3"x16" Metal Deck 10' Span |
3"x16" 20 Ga. Metal Roof Panel for Open Canopies - 10' Span |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +65/-65 Other: Tested in accordance with ASTM E1592-05. Must be installed in accordance with FBC and Manufactures Installation Instructions for roof slopes less than 2:12. Deflection is limited to L/240. |
Installation Instructions FL10668_R5_II_A1.2 METAL DECK TEST WGA07980-1Stamped.pdf Verified By: American Test Lab Inc Test Reports FL10668_R5_TR_1013.01-14.pdf |
|
|
| 10668.3 |
3"x16" Metal Deck 12' Span 3"x16" 20 Ga. Metal Roof Panel for Open Canopies - 12' Span |
3"x16" 20 Ga. Metal Roof Panel for Open Canopies - 12' Span |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +55/-55 Other: Tested in accordance with ASTM E1592-05. Must be installed in accordance with FBC and Manufactures Installation Instructions for roof slopes less than 2:12. Deflection is limited to L/240. |
Installation Instructions FL10668_R5_II_A1.3 METAL DECK TEST WGA07980-1Stamped.pdf Verified By: American Test Lab Inc Test Reports FL10668_R5_TR_1014.01-14.pdf |
|
|
| 10668.4 |
3"x16" Metal Deck 8' Span |
3"x16" 20 Ga. Metal Roof Panel for Open Canopies - 8' Span |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +90/-90 Other: Tested in accordance with ASTM E1592-05. Must be installed in accordance with FBC and Manufactures Installation Instructions for roof slopes less than 2:12. Deflection is limited to L/240. |
Installation Instructions FL10668_R5_II_A1.1 METAL DECK TEST WGA07980-1Stamped.pdf Verified By: American Test Lab Inc Test Reports FL10668_R5_TR_1008.02-14.pdf |