| 46679.1 |
01: Rib on battens |
29ga (min) rib panel on 1x4 SYP (nom, or better) battens on 7/16" (min) OSB |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-86 Other: See evaluation report |
Installation Instructions FL46679_R3_II_Rib_29ga_battens_OSB.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL46679_R3_AE_Rib_29ga_battens_OSB.pdf Created by Independent Third Party: Yes |
|
|
| 46679.2 |
02: Rib on plywood |
29ga (min) rib panel on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-56 Other: See evaluation report |
Installation Instructions FL46679_R3_II_Rib_29ga_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL46679_R3_AE_Rib_29ga_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 46679.3 |
03: 1.75-in Snaplock on plywood |
24ga (min) 1.75" snaplock on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-78.5 Other: See evaluation report. |
Installation Instructions FL46679_R3_II_175_Snaplock_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL46679_R3_AE_175_Snaplock_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 46679.4 |
04: 1-in Nailstrip on plywood |
26ga (min) 1" nailstrip on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-91.8 Other: See evaluation report. |
Installation Instructions FL46679_R3_II_100_nailstrip_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL46679_R3_AE_100_nailstrip_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 46679.5 |
05: PBR on purlins |
26ga (min) PBR on 16ga (min) purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-65 Other: See evaluation report. |
Installation Instructions FL46679_R3_II_PBR_26ga_16ga.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL46679_R3_AE_PBR_26ga_16ga.pdf Created by Independent Third Party: Yes |
|
|
| 46679.6 |
06: 1.5-in Nailstrip on plywood |
24ga (min) 1.5" nailstrip on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-60.55 Other: See evaluation report. |
Installation Instructions FL46679_R3_II_150_nailstrip_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL46679_R3_AE_150_nailstrip_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 46679.7 |
07: Rib on wood purlins |
29ga (min) rib panel on 2x6 SYP (nom, or better) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-91.5 Other: See evaluation report. |
Installation Instructions FL46679_R3_II_Rib_29ga_2x.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL46679_R3_AE_Rib_29ga_2x.pdf Created by Independent Third Party: Yes |
|
|
| 46679.8 |
08: 5V on battens |
26ga (min) 5V panel on 1x4 SYP (nom, or better) battens on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-115.25 Other: See evaluation report. |
Installation Instructions FL46679_R3_II_5V_26ga_battens_pywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL46679_R3_AE_5V_26ga_battens_pywood.pdf Created by Independent Third Party: Yes |
|
|
| 46679.9 |
09: Rib on OSB |
29ga (min) rib panel on 7/16" OSB (min) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-41.65 Other: See evaluation report. |
Installation Instructions FL46679_R3_II_Rib_29ga_OSB.pdf Verified By: David Eng PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL46679_R3_AE_Rib_29ga_OSB.pdf Created by Independent Third Party: Yes |