| 46635.1 |
01: 26ga 1" Nailstrip on plywood |
26ga (min) nominally 1" tall nailstrip panel on 15/32" (min) plywood or 3/4" wood plank. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-176 Other: See evaluation report. |
Installation Instructions FL46635_R0_II_26ga_100SL_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL46635_R0_AE_26ga_100SL_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 46635.2 |
02: 24ga 1" Nailstrip on plywood |
24ga (min) nominally 1" tall nailstrip panel on 15/32" (min) plywood or 3/4" wood plank. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-206 Other: See evaluation report. |
Installation Instructions FL46635_R0_II_24ga_100SL_plywood_nonHVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL46635_R0_AE_24ga_100SL_plywood_nonHVHZ.pdf Created by Independent Third Party: Yes |
|
|
| 46635.3 |
03: 032 Aluminum 1" Nailstrip on plywood |
Nominally 0.032" aluminum or thicker nominally 1" tall nailstrip panel on 15/32" (min) plywood or 3/4" wood plank. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-175 Other: See evaluation report. |
Installation Instructions FL46635_R0_II_032Al_100SL_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL46635_R0_AE_032Al_100SL_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 46635.4 |
04: 26ga 1" Nailstrip on plywood |
26ga (min) nominally 1" tall nailstrip panel on 15/32" (min) plywood or 3/4" wood plank. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-108.5 Other: See evaluation report. |
Installation Instructions FL46635_R0_II_26ga_100SL_plywood_nonHVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL46635_R0_AE_26ga_100SL_plywood_nonHVHZ.pdf Created by Independent Third Party: Yes |
|
|
| 46635.5 |
05: 032 Aluminum 1" Nailstrip on plywood |
Nominally 0.032" aluminum or thicker nominally 1" tall nailstrip panel on 15/32" (min) plywood or 3/4" wood plank. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-153.5 Other: See evaluation report. |
Installation Instructions FL46635_R0_II_032Al_100SL_plywood_nonHVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL46635_R0_AE_032Al_100SL_plywood_nonHVHZ.pdf Created by Independent Third Party: Yes |
|
|
| 46635.6 |
06: 24ga 1.5" Nailstrip on plywood |
24ga (min) nominally 1.5" tall nailstrip panel on 15/32" (min) plywood or 3/4" wood plank. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-153.5 Other: See evaluation report. |
Installation Instructions FL46635_R0_II_24ga_150SL_plywood_nonHVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL46635_R0_AE_24ga_150SL_plywood_nonHVHZ.pdf Created by Independent Third Party: Yes |
|
|
| 46635.7 |
07: 032 Aluminum 1.5" Nailstrip on plywood |
Nominally 0.032" aluminum or thicker nominally 1.5" tall nailstrip panel on 15/32" (min) plywood or 3/4" wood plank. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-168.5 Other: See evaluation report. |
Installation Instructions FL46635_R0_II_032Al_150SL_plywood_nonHVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL46635_R0_AE_032Al_150SL_plywood_nonHVHZ.pdf Created by Independent Third Party: Yes |
|
|
| 46635.8 |
08: 24ga 1.5" Nailstrip on plywood |
24ga (min) nominally 1.5" tall nailstrip panel on 15/32" (min) plywood or 3/4" wood plank. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-112.5 Other: See evaluation report. |
Installation Instructions FL46635_R0_II_24ga_150SL_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL46635_R0_AE_24ga_150SL_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 46635.9 |
09: 032 Aluminum 1.5" Nailstrip on plywood |
Nominally 0.032" aluminum or thicker nominally 1.5" tall nailstrip panel on 15/32" (min) plywood or 3/4" wood plank. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-179.5 Other: See evaluation report. |
Installation Instructions FL46635_R0_II_032Al_150SL_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL46635_R0_AE_032Al_150SL_plywood.pdf Created by Independent Third Party: Yes |