| 46648.1 |
01: Steel 1.5" Mechanical on Plywood |
24ga (min) steel 1.5" mechanical seam on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-198.5 Other: See evaluation report. |
Installation Instructions FL46648_R0_II_24ga_150MS_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL46648_R0_AE_24ga_150MS_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 46648.2 |
02: Aluminum 1.5" Mechanical on Plywood |
Nominally 0.032" aluminum or thicker 1.5" mechanical seam on (min) 15/32" plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-213.5 Other: See evaluation report. |
Installation Instructions FL46648_R0_II_032Al_150MS_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL46648_R0_AE_032Al_150MS_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 46648.3 |
03: Steel 1.5" Mechanical on Plywood |
26ga (min) steel 1.5" mechanical seam on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-218.8 Other: See evaluation report. |
Installation Instructions FL46648_R0_II_26ga_150MS_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL46648_R0_AE_26ga_150MS_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 46648.4 |
04: Steel 1.5" Mechanical on Plywood |
24ga (min) steel 1.5" mechanical seam on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-189.25 Other: See evaluation report. |
Installation Instructions FL46648_R0_II_24ga_150MS_plywood_20-in.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL46648_R0_AE_24ga_150MS_plywood_20-in.pdf Created by Independent Third Party: Yes |
|
|
| 46648.5 |
05: Steel 2" Mechanical on Plywood |
24ga (min) steel 2" mechanical seam on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-228.5 Other: See evaluation report. |
Installation Instructions FL46648_R0_II_24ga_200MS_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL46648_R0_AE_24ga_200MS_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 46648.6 |
06: Aluminum 2" Mechanical on Plywood |
Nominally 0.032" aluminum or thicker 2" mechanical seam on 15/32" (min) plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-200 Other: See evaluation report. |
Installation Instructions FL46648_R0_II_032Al_200MS_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL46648_R0_AE_032Al_200MS_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 46648.7 |
07: Steel 2" Mechanical on Steel Deck |
24ga (min) steel 2" mechanical seam on 22ga (min) steel deck |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-148 Other: See evaluation report. |
Installation Instructions FL46648_R0_II_24ga_200MS_BDeck.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL46648_R0_AE_24ga_200MS_BDeck.pdf Created by Independent Third Party: Yes |
|
|
| 46648.8 |
08: Steel 2" Mechanical on Steel Deck |
24ga (min) steel 2" mechanical seam on 22ga (min) steel deck |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-181.75 Other: See evaluation report. |
Installation Instructions FL46648_R0_II_24ga_200MS_BDeck_b.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL46648_R0_AE_24ga_200MS_BDeck_b.pdf Created by Independent Third Party: Yes |