| 19663.1 |
MRM Tornado Aluminum Roof Panel 1.5 |
Max 18" wide, nom 0.036" thick (min.) aluminum standing seam panel over min 19/32" thick plywood deck |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-213.5 Other: Uplift load of 142.25 psf at max. clip spacing of 18" o.c. with single lock seam. Uplift load of 213.5 psf at max. clip spacing of 14" o.c. with double lock seam. |
Installation Instructions FL19663_R2_II_EvaluationReportC2873_1.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL19663_R2_AE_EvaluationReportC2873_1.pdf Created by Independent Third Party: Yes |
|
|
| 19663.2 |
MRM Tornado Steel Roof Panel 1.5 |
Max 20" wide, min 24 ga. standing seam metal panel over min 19/32" thick plywood deck |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-236 Other: Uplift load of 172.25 psf at max. clip spacing of 18" o.c. with single lock seam. Uplift load of 236 psf at max. clip spacing of 12" o.c. with double lock seam |
Installation Instructions FL19663_R2_II_EvaluationReportC2873_2.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL19663_R2_AE_EvaluationReportC2873_2.pdf Created by Independent Third Party: Yes |