Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL19665-R5
Application Type Revision
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Greenheck Fan Corporation
Address/Phone/Email 400 Ross Ave
PO Box 410
Schofield, WI 54476
(715) 355-2242
mike.steele@greenheck.com
 
Authorized Signature Michael Steele
mike.steele@greenheck.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Panel Walls
Subcategory Wall Louver
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Robert Nangia
Florida License PE-69555
Quality Assurance Entity PRI Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date 12/31/2027
Validated By Locke Bowden P.E.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL19665_R5_COI_19665 EHH-601DE PE Eval Report 6-26-2025.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
AMCA 5402013
AMCA 5502022
TAS 2011994
TAS 2021994
TAS 2031994
 
Equivalence of Product Standards
Certified By

Florida Licensed Professional Engineer or Architect
FL19665_R5_Equiv_19665 EHH-601DE PE Eval Report 6-26-2025.pdf
 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 10/19/2023
Date Validated 07/16/2025
Date Pending FBC Approval 07/22/2025
Date Approved 10/14/2025
 
Summary of Products
FL # Model, Number or Name Description
19665.1 EHH-601DE Hurricane Louver (Channel Frame) 6" Deep Horizontal Blade Louver with Channel Frame, Extruded Aluminum, Impact & Pressure Resistant with Option for High Velocity Wind Driven Rain Resistance
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +150/-150
 Other: Allowable Stress Design (ASD). Rated for AMCA 540 Enhanced Protection Missile Impact Level E (80 fps) without TAS 203 Cyclic. Rated for TAS 201 Basic Missile Impact Level D (50 fps) with TAS 203 Cyclic. Passed AMCA 550 with Fully Closed VCD-40 Damper. Substrates Include: Concrete (Non-Cracked), Grout Filled CMU, Steel, Aluminum & Wood. See FL19665.2 (Flange w/ Sleeve Frame) for Cracked Concrete Substrate.
Installation Instructions
 FL19665_R5_II_19665 EHH-601DE PE Eval Report 6-26-2025.pdf
 Verified By: Robert Nangia 69555
 Created by Independent Third Party: Yes
Evaluation Reports
 FL19665_R5_AE_19665 EHH-601DE PE Eval Report 6-26-2025.pdf
 Created by Independent Third Party: Yes
19665.2 EHH-601DE Hurricane Louver (Flange w/ Sleeve Frame) 6" Deep Horizontal Blade Louver with Flange w/ Sleeve Frame, Extruded Aluminum, Impact & Pressure Resistant with Option for High Velocity Wind Driven Rain Resistance
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +150/-150
 Other: Allowable Stress Design (ASD). Rated for AMCA 540 Enhanced Protection Missile Impact Level E (80 fps) without TAS 203 Cyclic. Rated for TAS 201 Basic Missile Impact Level D (50 fps) with TAS 203 Cyclic. Passed AMCA 550 with Fully Closed VCD-40 Damper. Substrates Include: All Types via Anchorless Flange Capture.
Installation Instructions
 FL19665_R5_II_19665 EHH-601DE PE Eval Report 6-26-2025.pdf
 Verified By: Robert Nangia 69555
 Created by Independent Third Party: Yes
Evaluation Reports
 FL19665_R5_AE_19665 EHH-601DE PE Eval Report 6-26-2025.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts: