FL # FL44601-R0
Application Type New
Code Version 2023
Application Status Approved
  *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
 
Comments
Archived
 
Product Manufacturer Western States Metal Roofing
Address/Phone/Email 901 W. Watkins Street
Phoenix, AZ
(602) 495-0048   Ext 106
mark@westernstatesmetalroofing.com
 
Authorized Signature Mark Fields
mark@westernstatesmetalroofing.com
 
Technical Representative Mark Fields
Address/Phone/Email 901 W. Watkins Street
Phoenix, AZ 85007
(602) 495-0048   Ext 106
mark@westernstatesmetalroofing.com
 
Quality Assurance Representative
Address/Phone/Email
 
Category Roofing
Subcategory Metal Roofing
 
Compliance Method Evaluation Report from a Product Evaluation Entity
 
Evaluation Entity ICC Evaluation Service, LLC
Quality Assurance Entity ICC Evaluation Service
Quality Assurance Contract Expiration Date 11/30/2024
Validated By ICC Evaluation Services, LLC
 
 
Certificate of Independence
 
Referenced Standard and Year (of Standard)
StandardYear
AAMA 14022009
ASTM E1362019
ASTM E15922017
UL 5802006
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option C
 
Date Submitted 12/04/2023
Date Validated 12/05/2023
Date Pending FBC Approval
Date Approved 12/06/2023
Date Revised 02/06/2025
 
Summary of Products
          Page 1 / 2    
FL # Model, Number or Name Description
44601.1 7/8" Corrugated Exposed Fastener, Metal Roofing Panels. Installed over 15/32" Plywood.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +0/-60
 Other: When the Panels are installed over solid or closely fitted decking, allowable positive wind load is limited to the capacity of the decking.
Installation Instructions
 FL44601_R0_II_ESR-4729.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL44601_R0_AE_ESR-4729.pdf
44601.2 7/8" Corrugated Exposed Fastener, Metal Roofing Panels. Installed over 7/16" OSB.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +0/-41
 Other: When the Panels are installed over solid or closely fitted decking, allowable positive wind load is limited to the capacity of the decking.
Installation Instructions
 FL44601_R0_II_ESR-4729.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL44601_R0_AE_ESR-4729.pdf
44601.3 7/8" Corrugated Exposed .032 Aluminum Metal Roofing Panels. Installed Over 15/32" Plywood.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +0/-60
 Other: When the Panels are installed over solid or closely fitted decking, allowable positive wind load is limited to the capacity of the decking.
Installation Instructions
 FL44601_R0_II_ESR-4729.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL44601_R0_AE_ESR-4729.pdf
44601.4 7/8" Corrugated Exposed 20 oz. Copper Roofing Panels. Installed Over 15/32" Plywood Substrate.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +0/-75
 Other: When the Panels are installed over solid or closely fitted decking, allowable positive wind load is limited to the capacity of the decking.
Installation Instructions
 FL44601_R0_II_ESR-4729.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL44601_R0_AE_ESR-4729.pdf
44601.5 7/8" Corrugated Exposed Metal Roofing Panels. Installed Over Minimum 16 GA Steel Spaced Supports.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +103/-68
 Other:  
Installation Instructions
 FL44601_R0_II_ESR-4729.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL44601_R0_AE_ESR-4729.pdf
44601.6 MS2 Mechanically Seamed Metal Roofing Panel. Installed Over 15/32" Plywood or 7/16" OSB.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +0/-52
 Other: When the Panels are installed over solid or closely fitted decking, allowable positive wind load is limited to the capacity of the decking.
Installation Instructions
 FL44601_R0_II_ESR-4729.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL44601_R0_AE_ESR-4729.pdf
44601.7 MS2 Mechanically Seamed Metal Roofing Panels. Installed Over Minimum 16GA Steel Spaced Supports.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +127/-42
 Other:  
Installation Instructions
 FL44601_R0_II_ESR-4729.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL44601_R0_AE_ESR-4729.pdf
44601.8 PBR-Panel Exposed Fastener Metal Roofing Panels. Installed Over 15/32" Plywood.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +0/-67
 Other: When the Panels are installed over solid or closely fitted decking, allowable positive wind load is limited to the capacity of the decking.
Installation Instructions
 FL44601_R0_II_ESR-4729.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL44601_R0_AE_ESR-4729.pdf
44601.9 PBR-Panel Exposed Fastener Metal Roofing Panels. Installed Over 7/16" OSB
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +0/-52
 Other: When the Panels are installed over solid or closely fitted decking, allowable positive wind load is limited to the capacity of the decking.
Installation Instructions
 FL44601_R0_II_ESR-4729.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL44601_R0_AE_ESR-4729.pdf
44601.10 PBR-Panel Exposed Fastener .032 Aluminum Metal Roofing Panels. Installed Over 15/32" Plywood.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +0/-52
 Other: When the Panels are installed over solid or closely fitted decking, allowable positive wind load is limited to the capacity of the decking.
Installation Instructions
 FL44601_R0_II_ESR-4729.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL44601_R0_AE_ESR-4729.pdf
44601.11 PBR-Panel Exposed Fastener Metal Roofing Panels. Installed Over Minimum 16GA Steel Spaced Supports.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +143/-122
 Other:  
Installation Instructions
 FL44601_R0_II_ESR-4729.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL44601_R0_AE_ESR-4729.pdf
44601.12 Thin Lock Hidden Fastener Metal Roofing Panel. Installed Over 15/32" Plywood or 7/16" OSB.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +0/-21
 Other: When the Panels are installed over solid or closely fitted decking, allowable positive wind load is limited to the capacity of the decking.
Installation Instructions
 FL44601_R0_II_ESR-4729.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL44601_R0_AE_ESR-4729.pdf
44601.13 Thin Lock Hidden Fastener Metal Roofing Panels. Installed Over Minimum 16GA Steel Spaced Supports.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +96/-16
 Other:  
Installation Instructions
 FL44601_R0_II_ESR-4729.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL44601_R0_AE_ESR-4729.pdf
44601.14 Western Lock Hidden Fastener Metal Roofing Panels. Installed over 15/32" Plywood.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +0/-52
 Other: When the Panels are installed over solid or closely fitted decking, allowable positive wind load is limited to the capacity of the decking.
Installation Instructions
 FL44601_R0_II_ESR-4729.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL44601_R0_AE_ESR-4729.pdf
44601.15 Western Lock Hidden Fastener Metal Roofing Panels. Installed Over 7/16" OSB.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +0/-45
 Other: When the Panels are installed over solid or closely fitted decking, allowable positive wind load is limited to the capacity of the decking.
Installation Instructions
 FL44601_R0_II_ESR-4729.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL44601_R0_AE_ESR-4729.pdf
44601.16 Western Lock Hidden Fastener .032 Aluminum Metal Roofing Panels. Installed Over 15/32" Plywood.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +0/-45
 Other: When the Panels are installed over solid or closely fitted decking, allowable positive wind load is limited to the capacity of the decking.
Installation Instructions
 FL44601_R0_II_ESR-4729.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL44601_R0_AE_ESR-4729.pdf
44601.17 Western Lock Hidden Fastener 20 oz. Roofing Panels. Installed Over 15/32" Plywood.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +0/-52
 Other: When the Panels are installed over solid or closely fitted decking, allowable positive wind load is limited to the capacity of the decking.
Installation Instructions
 FL44601_R0_II_ESR-4729.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL44601_R0_AE_ESR-4729.pdf
44601.18 Western Lock Hidden Fastener Metal Roofing Panels. Installed Over Minimum 16GA Steel Spaced Supports.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +101/-21
 Other:  
Installation Instructions
 FL44601_R0_II_ESR-4729.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL44601_R0_AE_ESR-4729.pdf
44601.19 Western Rib Exposed Fastener Metal Roofing Panels. Installed over 15/32" Plywood.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +0/-70
 Other: When the Panels are installed over solid or closely fitted decking, allowable positive wind load is limited to the capacity of the decking.
Installation Instructions
 FL44601_R0_II_ESR-4729.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL44601_R0_AE_ESR-4729.pdf
44601.20 Western Rib Exposed Fastener Metal Roofing Panel. Installed Over 7/16" OSB
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +0/-52
 Other: When the Panels are installed over solid or closely fitted decking, allowable positive wind load is limited to the capacity of the decking.
Installation Instructions
 FL44601_R0_II_ESR-4729.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL44601_R0_AE_ESR-4729.pdf
          Page 1 / 2    
 