| 34010.1 |
.1 Roll Up Shutter / Wind Borne Debris Region RLL-3 Slat /HVHZ |
Extruded aluminum slats interlocked together thru knuckles and retained by tracks to provide hurricane protection. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: No Impact Resistant: Yes Design Pressure: +varies/-varies Other: Large missile impact resistant. ASD pressure rating, +/- 25 psf at 5'-11" spans with RLL-3 slat. See remaining pressures and spans on sheet 11 of installation drawings. |
Installation Instructions FL34010_R1_II_ROLLAC SHUTTERS OF TEXAS PED 25-054.pdf Verified By: Walter A. Tillit Jr., P.E. PE 44167 Created by Independent Third Party: Yes Evaluation Reports FL34010_R1_AE_ROLLAC SHUTTERS OF TEXAS PER 25-054.pdf Created by Independent Third Party: Yes |
|
|
| 34010.2 |
.2 FLL 55-X Slat End Retention Impact Protection System / HVHZ |
Extruded aluminum slats interlocked together thru knuckles and retained by tracks to provide hurricane protection. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: No Impact Resistant: Yes Design Pressure: +varies/-varies Other: Large missile (50 ft/sec) impact resistant. ASD pressure rating, +/- 30 psf at 19'-8" span and +/- 160 psf at 6'-9" span with 3/16" slip. See sheets 10 and 18 of installation drawing for additional pressures and spans. |
Installation Instructions FL34010_R1_II_ROLLAC SHUTTERS OF TEXAS PED 25-055.pdf Verified By: Walter A. Tillit Jr., PE PE44167 Created by Independent Third Party: Yes Evaluation Reports FL34010_R1_AE_ROLLAC SHUTTERS OF TEXAS PER 25-055.pdf Created by Independent Third Party: Yes |