| 4133.1 |
BR5-36 |
Exposed Fastener Metal Roof Panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See evaluation report for load/span tables and installation options. The use of this panel as a shear diaphragm is outside the scope of this product approval. Minimum roof slope for this product is 2:12. See attached document under Installation Instructions "Section 1711_ACE_Letter_Rev1_ss.pdf" for information related to 2026 FBC, Section 1711, corrosion resistance of installation fasteners. |
Installation Instructions FL4133_R9_II_ExposedMetalFastenerRoofPanel_Issue1_ss.pdf FL4133_R9_II_Section 1711_ACE_Letter_Rev1_ss.pdf Verified By: Robert J. Amoruso, P.E. FL License No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL4133_R9_AE_ACE-PER-1150_Rev1_Exposed Fastener Metal Roof Panels_Appendices_ss.pdf Created by Independent Third Party: Yes |
|
|
| 4133.2 |
Style-Rib |
Exposed Fastener Metal Roof Panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See evaluation report for load/span tables and installation options. The use of this panel as a shear diaphragm is outside the scope of this product approval. Minimum roof slope for this product is 2:12. See attached document under Installation Instructions "Section 1711_ACE_Letter_Rev1_ss.pdf" for information related to 2026 FBC, Section 1711, corrosion resistance of installation fasteners. |
Installation Instructions FL4133_R9_II_ExposedMetalFastenerRoofPanel_Issue1_ss.pdf FL4133_R9_II_Section 1711_ACE_Letter_Rev1_ss.pdf Verified By: Robert J. Amoruso, P.E. FL License No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL4133_R9_AE_ACE-PER-1150_Rev1_Exposed Fastener Metal Roof Panels_Appendices_ss.pdf Created by Independent Third Party: Yes |
|
|
| 4133.3 |
TR4-36 |
Exposed Fastener Metal Roof Panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See evaluation report for load/span tables and installation options. The use of this panel as a shear diaphragm is outside the scope of this product approval. Minimum roof slope for this product is 2:12. See attached document under Installation Instructions "Section 1711_ACE_Letter_Rev1_ss.pdf" for information related to 2026 FBC, Section 1711, corrosion resistance of installation fasteners. |
Installation Instructions FL4133_R9_II_ExposedMetalFastenerRoofPanel_Issue1_ss.pdf FL4133_R9_II_Section 1711_ACE_Letter_Rev1_ss.pdf Verified By: Robert J. Amoruso, P.E. FL License No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL4133_R9_AE_ACE-PER-1150_Rev1_Exposed Fastener Metal Roof Panels_Appendices_ss.pdf Created by Independent Third Party: Yes |