| 1573.1 |
CertainTeed Vinyl Siding |
Vinyl Siding |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-115.6 Other: 1.) This application shall not be used for soffit products. 2.) Refer to FBC Supplement for determination of design wind loads. 3.) DP noted in this application pertains to one system. Refer to Table 2 of the ICC-ESR for specific systems and associated Allowable Negative Wind Loads. 4.) Fasteners and connectors, if applicable, in areas within 3000 feet of a saltwater coastline shall demonstrate compliance with FBC 1711 to the satisfaction of the Authority Having Jurisdiction. |
Installation Instructions FL1573_R9_II_ESR-1066 06-26.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL1573_R9_AE_ESR-1066 06-26.pdf |
|
|
| 1573.2 |
Restoration Millwork Exterior Trim and CertaTrim |
Rigid cellular PVC solid cross sections installed as trim pieces |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-55.0 Other: 1.) This application shall not be used for soffit products. 2.) Refer to FBC Supplement for determination of design wind loads. 3.) DP noted in this application pertains to one system. Refer to Section 4.3 of the ICC-ESR for specific systems and associated Allowable Negative Wind Loads. 4.) Fasteners and connectors, if applicable, in areas within 3000 feet of a saltwater coastline shall demonstrate compliance with FBC 1711 to the satisfaction of the Authority Having Jurisdiction. |
Installation Instructions FL1573_R9_II_ESR-2922 07-26.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL1573_R9_AE_ESR-2922 07-26.pdf |
|
|
| 1573.3 |
Vinyl Carpentry |
Vinyl Siding |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-57.7 Other: 1.) This application shall not be used for soffit products. 2.) Refer to FBC Supplement for determination of design wind loads. 3.) DP noted in this application pertains to one system. Refer to Table 2 of the ICC-ESR for specific systems and associated Allowable Negative Wind Loads. 4.) Fasteners and connectors, if applicable, in areas within 3000 feet of a saltwater coastline shall demonstrate compliance with FBC 1711 to the satisfaction of the Authority Having Jurisdiction. |
Installation Instructions FL1573_R9_II_ESR-1066 06-26.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL1573_R9_AE_ESR-1066 06-26.pdf |