| 19278.1 |
SCV501MD Hurricane Louver |
5" Deep Vertical Blade Louver, Extruded Aluminum, High Velocity Wind Driven Rain Resistant, Impact & Pressure Resistant |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +130/-130 Other: Allowable Stress Design (ASD). Rated for AMCA 540 Enhanced Protection Missile Impact Level E (80 fps) without TAS 203 Cyclic. Rated for TAS 201 Basic Missile Impact Level D (50 fps) with TAS 203 Cyclic. Passed AMCA 550 with Blades Fully Open. Channel Frame Substrates Include: Cracked Concrete, Grout Filled CMU, Steel, Aluminum & Wood. Flanged & Sleeved Frame Substrates Include: All Substrates via Anchorless Flange. |
Installation Instructions FL19278_R8_II_FPA 19278 SCV501MD PE Eval Report 2025-06-15.pdf Verified By: Robert Nangia 69555 Created by Independent Third Party: Yes Evaluation Reports FL19278_R8_AE_FPA 19278 SCV501MD PE Eval Report 2025-06-15.pdf Created by Independent Third Party: Yes |