| 6095.1 |
01: Pro Lok |
24 Ga. Pro Lok Roof Panel over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-86.75PSF Other: -86.75 psf @ 12" o.c. fastener spacing. |
Installation Instructions FL6095_R8_II_24ga_ProLoc_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL6095_R8_AE_24ga_ProLoc_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 6095.2 |
02: Super Pro |
26 Ga. Super Pro Roof Panel over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-168.5PSF Other: -71.75 psf at 9”-9”-9”-9” Fastener Pattern at 24” O.C.
-168.5 psf at 6.5”-2.5”-6.5”-2.5”-6.5”-2.5”-6.5” Fastener Pattern at 12” O.C. |
Installation Instructions FL6095_R8_II_26ga_SuperPro_Plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL6095_R8_AE_26ga_SuperPro_Plywood.pdf Created by Independent Third Party: Yes |
|
|
| 6095.3 |
03: Super Pro |
29 Ga. Super Pro Roof Panel over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-168.5PSF Other: -69.25 psf at 9”-9”-9”-9” Fastener Pattern at 24” O.C.
-168.5 psf at 6.5”-2.5”-6.5”-2.5”-6.5”-2.5”-6.5” Fastener Pattern at 12” O.C. |
Installation Instructions FL6095_R8_II_29ga_SuperPro_Plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL6095_R8_AE_29ga_SuperPro_Plywood.pdf Created by Independent Third Party: Yes |
|
|
| 6095.4 |
04: Super Pro |
29 Ga. Super Pro Roof Panel over 1x4 Wood Purlins over 7/16" OSB |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-191.0psf Other: - 108.5 psf at 9"-9"-9"-6" at 24" o.c. - 191.0 psf at 9"-9"-9"-6" at 12" o.c. |
Installation Instructions FL6095_R8_II_29ga_SuperPro_1x4s_OSB.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL6095_R8_AE_29ga_SuperPro_1x4s_OSB.pdf Created by Independent Third Party: Yes |
|
|
| 6095.5 |
05: Super Pro PBR |
Min. 26 Ga. Super Pro PBR Roof Panel over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-176.0psf Other: -63.5 psf at 12"-12"-12" at 24" o.c. - 176.0 psf at 7"-5"-7"-5"-7" at 12" o.c. |
Installation Instructions FL6095_R8_II_26ga_SuperPro_PBR_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL6095_R8_AE_26ga_SuperPro_PBR_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 6095.6 |
06: Super Pro PBR |
Min. 26 Ga. Super Pro PBR Roof Panel over 1x4 Wood Purlins over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-183.5 Other: -108.5 psf at 12"-12"-12" at 24" o.c. -183.5 psf at 7"-5"-7"-5"-7" at 12" o.c. |
Installation Instructions FL6095_R8_II_26ga_SuperPro_PBR_1x4.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL6095_R8_AE_26ga_SuperPro_PBR_1x4.pdf Created by Independent Third Party: Yes |
|
|
| 6095.7 |
07: Pro Loc |
Min. 26 Ga. Pro Lok Roof Panel over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116 Other: -78.5psf at 12" o.c., -116psf at 3" oc. |
Installation Instructions FL6095_R8_II_26ga_ProLoc_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL6095_R8_AE_26ga_ProLoc_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 6095.8 |
08: Pro Loc |
Nominal 0.032" or thicker aluminum Pro Lok Roof Panel over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-52.5 Other: -52.5psf at 12" o.c. |
Installation Instructions FL6095_R8_II_032Al_ProLok_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL6095_R8_AE_032Al_ProLok_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 6095.9 |
09: Super Pro |
Min. 29 Ga. Super Pro over 7/16" OSB |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-123.5 Other: -63.5psf with 6"-3" fastener pattern at 24" o.c. | -123.5psf with 6"-3" fastener pattern at 6" o.c. |
Installation Instructions FL6095_R8_II_29ga_SuperPro_OSB.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL6095_R8_AE_29ga_SuperPro_OSB.pdf Created by Independent Third Party: Yes |
|
|
| 6095.10 |
10: Super Pro |
Min. 26ga Super Pro over 7/16" OSB |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-123.5 Other: 9"-9" fastener pattern, -56.3 psf at 18" o.c., -89.9psf at 12" o.c., 123.5 psf at 6" o.c. |
Installation Instructions FL6095_R8_II_26ga_SuperPro_OSB.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL6095_R8_AE_26ga_SuperPro_OSB.pdf Created by Independent Third Party: Yes |
|
|
| 6095.11 |
11: Super Pro |
Min. 29ga Super Pro over 7/16" OSB |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116 Other: 9"-9" fastener pattern, -53.8 psf at 18" o.c., -84.9psf at 12" o.c., 116 psf at 6" o.c. |
Installation Instructions FL6095_R8_II_29ga_SuperPro_7-16OSB_9-9.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL6095_R8_AE_29ga_SuperPro_7-16OSB_9-9.pdf Created by Independent Third Party: Yes |
|
|
| 6095.12 |
12: Super Pro |
Min. 29ga Super Pro over 19/32" OSB |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-131 Other: 9"-9" fastener pattern, -63.5psf at 24" o.c., -86 psf at 18" o.c., -108.5psf at 12" o.c., 131 psf at 6" o.c. |
Installation Instructions FL6095_R8_II_29ga_SuperPro_19-32OSB_9-9.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL6095_R8_AE_29ga_SuperPro_19-32OSB_9-9.pdf Created by Independent Third Party: Yes |