| 39517.1 |
Elite Rib Roof Panel |
29 ga Elite Rib Roof Panel Over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-83.9 Other: Per UL580 / UL1897 Tests with fasteners spaced at 24" on centers over 15/32" plywood with Safety Factor of 2.0 . Materials and Installation shall be per Sections 1506 and 1507.4 of the 2023 FBC Building Code. |
Installation Instructions FL39517_R1_II_T215-21.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL39517_R1_TR_T215-21.pdf |
|
|
| 39517.2 |
Elite Rib Roof Panel |
29 ga Elite Rib Roof Panel Over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-168.5 Other: Per UL580 / UL1897 Tests with fasteners spaced at 12" on centers over 15/32" plywood with Safety Factor of 2.0 . Materials and Installation shall be per Sections 1506 and 1507.4 of the 2023 FBC Building Code. |
Installation Instructions FL39517_R1_II_T214-21.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL39517_R1_TR_T214-21.pdf |
|
|
| 39517.3 |
Elite Rib Roof Panel |
29 ga Elite Rib Roof Panel Over 1X4 Wood Purlins Over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-112.5 Other: Per Ul580 / UL1897 Tests with fasteners at a 9/9/9/6 pattern over 1X4 wood purlins spaced at 24" on centers over 15/32" plywood with Safety Factor of 2.0 . Materials and Installation shall be per Sections 1506 and 1507.4 of the 2023 FBC Building Code. |
Installation Instructions FL39517_R1_II_T221-21.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL39517_R1_TR_T221-21.pdf |
|
|
| 39517.4 |
Elite Rib Roof Panel |
29 ga Elite Rib Roof Panel Over 1X4 Wood Purlins Over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-138.8 Other: Per UL580 / UL1897 Tests with fasteners at a 6/3/6/3/6/3/6 pattern over 1X4 wood purlins spaced at 24" on centers over 15/32" plywood with Safety Factor of 2.0 . Materials and Installation shall be per Sections 1506 and 1507.4 of the 2023 FBC Building Code. |
Installation Instructions FL39517_R1_II_T222-21.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL39517_R1_TR_T222-21.pdf |