| 11968.1 |
0.050" Bertha Aluminum Storm Panel (2.25" Deep)- Non-HVHZ - Drawing Number 26-228 |
Corrugated aluminum storm panels retained or not by tracks to provide hurricane protection. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Large Missile. Max. span is 12'-11" for +30, -30 p.s.f. and 8'-2" for +75, -80 p.s.f. for mountings without "h" header. See sheet 5 of installation drawing for other spans and pressures. |
Installation Instructions FL11968_R7_II_Drawing 26-228.pdf Verified By: American Test Lab of South Florida, Inc. Created by Independent Third Party: Yes Evaluation Reports FL11968_R7_AE_PE. Report Drawing 26-228.pdf Created by Independent Third Party: Yes |
|
|
| 11968.2 |
24 Gage Galvanized Bertha Steel Storm Panel (2.25" Deep)- Non-HVHZ - Drawing Number 26-231 |
corrugated galvanized steel storm panels retained or not by tracks to provide hurricane protection. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Large Missile. Max. span is 9'-8" for +35, -40 p.s.f. and 7'-2" for +70, -80 p.s.f. for panels mounted without "H" header. See sheet 4 of installation drawing for other spans and pressures. |
Installation Instructions FL11968_R7_II_Drawing 26-231.pdf Verified By: American Test Lab of South Florida, Inc. Created by Independent Third Party: Yes Evaluation Reports FL11968_R7_AE_PE Report Drawing 26-231.pdf Created by Independent Third Party: Yes |
|
|
| 11968.3 |
Clear Bertha Storm Panels (2.25" Deep) - Drawing Number 26-229 |
corrugated polycarbonate storm panels retained or not by tracks to provide hurricane protection. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Large Missile. Max/ span is 10'-0" for +28, -28 p.s.f. A.S.D. and 4'-0" for +105, -110 p.s.f. A.S.D desgin load. See sheet 3 of installation drawings for other spans and pressures. |
Installation Instructions FL11968_R7_II_Drawing 26-229.pdf Verified By: American Test Lab of South Florida, Inc. Created by Independent Third Party: Yes Evaluation Reports FL11968_R7_AE_PE Report Drawing 26-229.pdf Created by Independent Third Party: Yes |