| 11964.1 |
0.050" Bertha Aluminum Storm Panel (2 inch)- Drawing number 23-164 |
Corrugated aluminum Storm Panels retained or not by tracks to provide hurricane protection. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Large missile. Max. span is 13'-0" for +30, -30 p.s.f. ASD and 4'-0" for +90, -130 p.s.f. ASD for retained panels. See sheet 2 of installation drawing for other spans and pressures. |
Installation Instructions FL11964_R6_II_Drawing 23-164.pdf Verified By: American Test Lab of South Florida, Inc. Created by Independent Third Party: Yes Evaluation Reports FL11964_R6_AE_Product Evaluation Report Drawing 23-164.pdf Created by Independent Third Party: Yes |
|
|
| 11964.2 |
24 Gage Bertha Galvanized Steel Panel (2 inch) - Drawing number 23-142 |
Corrugated steel storm panels retained or not by tracks to provide hurricane protection. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Large Missile. Max. span is 9'-10" for +32.6, -32.6 p.s.f. ASD and 2'-8" for +58.0, -58.0 p.s.f. ASD See sheet 2 of installation drawings for other spans and pressures. |
Installation Instructions FL11964_R6_II_Drawing 23-142.pdf Verified By: American Test Lab of South Florida, Inc. Created by Independent Third Party: Yes Evaluation Reports FL11964_R6_AE_PE Report Drawing 23-142.pdf Created by Independent Third Party: Yes |