Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL11969-R6
Application Type Revision
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Eastern Metal Supply
Address/Phone/Email 4268 Westroads Drive
West Palm Beach, FL 33407
(800) 432-2204
bfeeley@easternmetal.com
 
Authorized Signature Bill Feeley
bfeeley@easternmetal.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Shutters
Subcategory Storm Panels
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Walter A. Tillit, Jr.
Florida License PE-44167
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2027
Validated By John Henry Kampmann Jr.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL11969_R6_COI_Cerification of Independence Drawing 23-143.pdf
FL11969_R6_COI_Certificate of Independence Drawing 23-158.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
TAS 201, 202, 2031994
 
Equivalence of Product Standards
Certified By

Florida Licensed Professional Engineer or Architect
FL11969_R6_Equiv_Letter 23-450.pdf
 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 10/08/2023
Date Validated 10/17/2023
Date Pending FBC Approval 10/26/2023
Date Approved 12/12/2023
Date Revised 08/19/2026
 
Summary of Products
FL # Model, Number or Name Description
11969.1 0.030" Thick Galvanized Bertha Steel Storm Panels (2.25" Deep)- HVHZ- Drawing Number 23-143 Corrugated galvanized steel storm panels retained or not by tracks to provide hurricane protection.
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: N/A
 Other: Large Missile. Max. span is 8'-6" for +60, -70 p.s.f. ASD for panels mounted per sections number 1 thru 5 and 8. See sheet 4 of installation drawing for other spans and pressures.
Installation Instructions
 FL11969_R6_II_Drawing 23-143.pdf
 Verified By: American Test Lab of South Florida, Inc.
 Created by Independent Third Party: Yes
Evaluation Reports
 FL11969_R6_AE_Product Evaluation Report Drawing 23-143.pdf
 Created by Independent Third Party: Yes
11969.2 0.050" Bertha Aluminum Storm Panel - HVHZ- Drawing Number 23-158 Corrugated aluminum storm panels retained or not by tracks to provide hurricane protection.
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: N/A
 Other: Large Missile. Max. span is 10'-0" for +62, -73.3 p.s.f. ASD and for mountings number 2, 6, 7 and 8. See sheet 9 of installation drawing for other spans and pressures.
Installation Instructions
 FL11969_R6_II_Drawing 23-158.pdf
 Verified By: American Test Lab of South Florida, Inc.
 Created by Independent Third Party: Yes
Evaluation Reports
 FL11969_R6_AE_Product Evaluation Report Drawing 23-158.pdf
 Created by Independent Third Party: Yes
 