| 11917.1 |
Artisan L-12 |
Min 24 ga., max 12" wide, 1" deep concealed fastened wall panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +60.0/-85.0 Other: Allowable load of +60/-50 psf at support spacing of 48" o.c. and -85 psf at support spacing of 12" o.c. |
Installation Instructions FL11917_R4_II_EvaluationReportC2423_1.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL11917_R4_AE_EvaluationReportC2423_1.pdf Created by Independent Third Party: Yes |
|
|
| 11917.2 |
AVP Panel |
Min 26 ga., 36" wide through fastened wall panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +23.4/-161.3 Other: Allowable load of +23.4/-22.1 psf at support spacing of 96" o.c. and -161.3 psf at support spacing of 24" o.c |
Installation Instructions FL11917_R4_II_EvaluationReportC2423_2.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL11917_R4_AE_EvaluationReportC2423_2.pdf Created by Independent Third Party: Yes |
|
|
| 11917.3 |
Designer Series Fluted Panel |
Min 24 ga., max 16" wide, 1.75" deep concealed fastened wall panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +30.0/-85.0 Other: Allowable load of +30/-17.5 psf at support spacing of 96" o.c. and -85 psf at support spacing of 24" o.c. |
Installation Instructions FL11917_R4_II_EvaluationReportC2423_3.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL11917_R4_AE_EvaluationReportC2423_3.pdf Created by Independent Third Party: Yes |
|
|
| 11917.4 |
FW-120 Panel |
Min 24 ga., max 12" wide, 1.5" deep concealed fastened wall panels |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +80.0/-151.0 Other: Allowable load of +80/-43.75 psf at support spacing of 48" o.c. and -151 psf at support spacing of 12" o.c. |
Installation Instructions FL11917_R4_II_EvaluationReportC2423_4.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL11917_R4_AE_EvaluationReportC2423_4.pdf Created by Independent Third Party: Yes |
|
|
| 11917.5 |
PBR Panel |
Min 29 ga., 36" wide through fastened wall panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +150.0/-142.5 Other: Allowable load of +150/-142.5 psf at support spacing of 48" o.c. for 22 ga. panels. |
Installation Instructions FL11917_R4_II_EvaluationReportC2423_5.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL11917_R4_AE_EvaluationReportC2423_5.pdf Created by Independent Third Party: Yes |
|
|
| 11917.6 |
ShadowRib Panel |
Min 24 ga., max 16" wide, 3" deep concealed fastened wall panels |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +45.0/-95.0 Other: Allowable load of +45/-17.5 psf at support spacing of 96" o.c. and -95 psf at support spacing of 24" o.c. |
Installation Instructions FL11917_R4_II_EvaluationReportC2423_6.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL11917_R4_AE_EvaluationReportC2423_6.pdf Created by Independent Third Party: Yes |