Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL11903-R4
Application Type Revision
Code Version 2020
Application Status Approved
 
Comments
Archived
 
Product Manufacturer MBCI
Address/Phone/Email 14031 West Hardy
Houston, TX 77060
(281) 445-8555   Ext 28612
jallen@ncilp.com
 
Authorized Signature Jason Allen
jallen@ncilp.com
 
Technical Representative Jason Allen
Address/Phone/Email 14031 West Hardy
Houston, TX 77060
(281) 445-8555   Ext 28612
jallen@ncilp.com
 
Quality Assurance Representative Jack Bell
Address/Phone/Email 14031 West Hardy
Houston, TX 77060
(281) 445-8555
jbell@mbci.com
 
Category Roofing
Subcategory Metal Roofing
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Bala Sockalingam
Florida License PE-62240
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/21/2023
Validated By Yoosef Lavi, P.E.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL11903_R4_COI_CertificateIndependence.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
TAS 1252003
UL 18972012
UL 5802006
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 12/19/2020
Date Validated 12/20/2020
Date Pending FBC Approval 12/26/2020
Date Approved 02/09/2021
 
Summary of Products
FL # Model, Number or Name Description
11903.1 5V-Crimp Min. 26 ga., 24" wide through fastened roof panel over min. 19/32” thick plywood deck with fasteners through panel rib.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-146
 Other: Uplift load of -74.8 psf at fastener spacing of 24" o.c. and -146 psf at fastener spacing of 12" o.c.
Installation Instructions
 FL11903_R4_II_EvaluationReportC2424_1.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL11903_R4_AE_EvaluationReportC2424_1.pdf
 Created by Independent Third Party: Yes
11903.2 Craftsman HB Min 24 ga., 16.5” wide metal roof panel with snap-on batten over plywood or metal deck
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-52.5
 Other: Uplift load of -52.5 psf @ clip spacing of 24" o.c.
Installation Instructions
 FL11903_R4_II_EvaluationReportC2424_2.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL11903_R4_AE_EvaluationReportC2424_2.pdf
 Created by Independent Third Party: Yes
11903.3 Craftsman SB Min 24 ga., 12” wide metal roof panel with snap-on batten over plywood deck
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-138.50
 Other: Uplift load of -54.3 @ clip spacing of 24" o.c. and -138.50 psf @ clip spacing of 6" o.c.
Installation Instructions
 FL11903_R4_II_EvaluationReportC2424_3.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL11903_R4_AE_EvaluationReportC2424_3.pdf
 Created by Independent Third Party: Yes
11903.4 Craftsman SB Min 24 ga., 16.5” wide metal roof panel with snap-on batten over plywood deck
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-71
 Other: Uplift load of -52.5 psf @ clip spacing of 24" o.c. and -71 psf @ clip spacing of 6" o.c.
Installation Instructions
 FL11903_R4_II_EvaluationReportC2424_4.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL11903_R4_AE_EvaluationReportC2424_4.pdf
 Created by Independent Third Party: Yes
11903.5 Lokseam Min 24 ga., 16" wide panel over min. 22 ga. metal deck
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-153.5
 Other: Uplift load of -52.5 psf at clip spacing of 48" o.c. and -153.5 psf at clip spacing of 6" o.c.
Installation Instructions
 FL11903_R4_II_EvaluationReportC2424_5.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL11903_R4_AE_EvaluationReportC2424_5.pdf
 Created by Independent Third Party: Yes
11903.6 Lokseam Min 24 ga., 16" wide panel over min. 19/32" plywood deck
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-101
 Other: Uplift load of -52.5 psf at clip spacing of 48" o.c. and -101.0 psf at clip spacing of 6" o.c.
Installation Instructions
 FL11903_R4_II_EvaluationReportC2424_6.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL11903_R4_AE_EvaluationReportC2424_6.pdf
 Created by Independent Third Party: Yes
11903.7 Slimline Panel Min 26 ga., 12" or 16" wide Slimline Panel over plywood deck
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-108.5
 Other: Uplift load of -52.5 psf at fastener spacing of 12" o.c. for 16" wide Panel. Uplift load of -56 psf at fastener spacing of 24" o.c. and -108.5 psf at fastener spacing of 6" o.c. for 12" wide Panel.
Installation Instructions
 FL11903_R4_II_EvaluationReportC2424_7.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL11903_R4_AE_EvaluationReportC2424_7.pdf
 Created by Independent Third Party: Yes
11903.8 Stormproof Panel Min. 29 ga., 36" wide Stormproof panel over shingles and min. 15/32" plywood
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-153.5
 Other: Uplift load of -71.0 psf at fastener spacing of 24" o.c. for Pattern A and -153.5 psf at fastener spacing of 12" o.c. for Pattern B.
Installation Instructions
 FL11903_R4_II_EvaluationReportC2424_8.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL11903_R4_AE_EvaluationReportC2424_8.pdf
 Created by Independent Third Party: Yes
11903.9 SuperLok Panel Min 24 ga., 16" wide panel over min. 22 ga. metal deck
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-151.5
 Other: Uplift load of -52.5 psf at clip spacing of 48" o.c. and -151.8 psf at clip spacing of 12" o.c.
Installation Instructions
 FL11903_R4_II_EvaluationReportC2424_9.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL11903_R4_AE_EvaluationReportC2424_9.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts: