| 7708.1 |
K6744X Hurricane Louver |
4" Deep Horizontal Blade Louver, Extruded Aluminum, UL Classified, Impact & Pressure Resistant |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +200/-200 Other: Allowable Stress Design (ASD). Load and Size Ratings in Accordance with the Attached Table. Rated for TAS 201 Basic Impact Missile Level D (50 fps) with TAS 203 Cyclic. Not Rated for AMCA 550. See FL35290 for Additional Approvals. Substrates Include: Concrete (Non-Cracked), Grout Filled CMU, Steel & Wood. |
Certification Agency Certificate FL7708_R11_C_CAC_Load and Size Tables R26078.pdf FL7708_R11_C_CAC_UL Quality Assurance Contract 12-31-2027.pdf Quality Assurance Contract Expiration Date 12/31/2027 Installation Instructions FL7708_R11_II_K6744X Install Details - Clip Angle Mount.pdf FL7708_R11_II_K6744X Install Details - Continuous Angle Mount.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 7708.2 |
K6746X Hurricane Louver |
6" Deep Horizontal Blade Louver, Extruded Aluminum, UL Classified, Impact & Pressure Resistant |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +200/-200 Other: Allowable Stress Design (ASD). Load and Size Ratings in Accordance with the Attached Table. Rated for TAS 201 Basic Impact Missile Level D (50 fps) with TAS 203 Cyclic. Not Rated for AMCA 550. See FL35290 for Additional Approvals. Substrates Include: Concrete (Non-Cracked), Grout Filled CMU, Steel & Wood. |
Certification Agency Certificate FL7708_R11_C_CAC_Load and Size Tables R26078.pdf FL7708_R11_C_CAC_UL Quality Assurance Contract 12-31-2027.pdf Quality Assurance Contract Expiration Date 12/31/2027 Installation Instructions FL7708_R11_II_K6746X Install Details - Clip Angle Mount.pdf FL7708_R11_II_K6746X Install Details - Continuous Angle Mount.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 7708.3 |
SCH501X Hurricane Louver |
5" Deep Horizontal Blade Louver, Extruded Aluminum, UL Classified, Impact & Pressure Resistant |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +200/-200 Other: Allowable Stress Design (ASD). Load and Size Ratings in Accordance with the Attached Table. Rated for TAS 201 Basic Impact Missile Level D (50 fps) with TAS 203 Cyclic. Not Rated for AMCA 550. See FL35290 for Additional Approvals. Substrates Include: Concrete (Non-Cracked), Grout Filled CMU, Steel & Wood. |
Certification Agency Certificate FL7708_R11_C_CAC_Load and Size Tables R26078.pdf FL7708_R11_C_CAC_UL Quality Assurance Contract 12-31-2027.pdf Quality Assurance Contract Expiration Date 12/31/2027 Installation Instructions FL7708_R11_II_SCH501X Install Details - Clip Angle Mount.pdf FL7708_R11_II_SCH501X Install Details - Continuous Angle Mount.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |