| 44502.1 |
7/8" Corrugated |
Exposed Fastener, Metal Wall Panels. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +0.0/-69.0 Other: Positive Wind Loads Are Limited To The Capacity Of The Supporting Substrate And Framing. |
Installation Instructions FL44502_R0_II_ESR-4730.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL44502_R0_AE_ESR-4730.pdf |
|
|
| 44502.2 |
Narrow Groove |
Narrow Groove® - Narrow Width
Metal Fascia, Soffit, And Wall Panel.
24GA Steel. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +0.0/-21 Other: Positive Wind Loads Are Limited To The Capacity Of The Supporting Substrate And Framing. |
Installation Instructions FL44502_R0_II_ESR-4730.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL44502_R0_AE_ESR-4730.pdf |
|
|
| 44502.3 |
Narrow Groove |
Narrow Groove® - Narrow Width
Metal Fascia, Soffit, And Wall Panel.
.032" Aluminum |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +0.0/-10 Other: Positive Wind Loads Are Limited To The Capacity Of The Supporting Substrate And Framing. |
Installation Instructions FL44502_R0_II_ESR-4730.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL44502_R0_AE_ESR-4730.pdf |
|
|
| 44502.4 |
Narrow Groove |
Narrow Groove® - Narrow Width
Metal Fascia, Soffit, And Wall Panel.
20oz Copper. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +0.0/-17 Other: Positive Wind Loads Are Limited To The Capacity Of The Supporting Substrate And Framing. |
Installation Instructions FL44502_R0_II_ESR-4730.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL44502_R0_AE_ESR-4730.pdf |
|
|
| 44502.5 |
PBR-Panel |
Exposed Fastener, Metal Wall Panel. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +0.0/-83 Other: Positive Wind Loads Are Limited To The Capacity Of The Supporting Substrate And Framing. |
Installation Instructions FL44502_R0_II_ESR-4730.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL44502_R0_AE_ESR-4730.pdf |
|
|
| 44502.6 |
T-8 Plankwall |
Concealed Fastener Metal Siding Panel. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +0.0/-48 Other: Positive Wind Loads Are Limited To The Capacity Of The Supporting Substrate And Framing. |
Installation Instructions FL44502_R0_II_ESR-4730.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL44502_R0_AE_ESR-4730.pdf |
|
|
| 44502.7 |
Western Lock |
Hidden Fastener, Standing Seam Metal Wall Panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +0.0/-76.0 Other: Positive Wind Loads Are Limited To The Capacity Of The Supporting Substrate And Framing. |
Installation Instructions FL44502_R0_II_ESR-4730.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL44502_R0_AE_ESR-4730.pdf |
|
|
| 44502.8 |
Western Reveal |
Concealed Fastener, Metal Fascia, Soffit, And Wall Panels. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +0.0/-28 Other: Positive Wind Loads Are Limited To The Capacity Of The Supporting Substrate And Framing. |
Installation Instructions FL44502_R0_II_ESR-4730.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL44502_R0_AE_ESR-4730.pdf |
|
|
| 44502.9 |
Western Rib |
Exposed Fastener, (7.2 Panel) Metal Wall Panel. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +0.0/-69.0 Other: Positive Wind Loads Are Limited To The Capacity Of The Supporting Substrate And Framing. |
Installation Instructions FL44502_R0_II_ESR-4730.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL44502_R0_AE_ESR-4730.pdf |
|
|
| 44502.10 |
Western Wave |
Concealed Fastener, Metal Wall Panel. Installed Vertically or Horizontally. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +0.0/-76 Other: Positive Wind Loads Are Limited To The Capacity Of The Supporting Substrate And Framing. |
Installation Instructions FL44502_R0_II_ESR-4730.pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL44502_R0_AE_ESR-4730.pdf |