FL # FL44502
Application Type New
Code Version 2023
Application Status Approved
  *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
 
Comments
Archived
 
Product Manufacturer Western States Metal Roofing
Address/Phone/Email 901 W. Watkins Street
Phoenix, AZ
(602) 495-0048   Ext 106
mark@westernstatesmetalroofing.com
 
Authorized Signature Mark Fields
mark@westernstatesmetalroofing.com
 
Technical Representative Mark Fields
Address/Phone/Email 901 W. Watkins Street
Phoenix, AZ 85007
(602) 495-0048   Ext 106
mark@westernstatesmetalroofing.com
 
Quality Assurance Representative
Address/Phone/Email
 
Category Structural Components
Subcategory Structural Wall
 
Compliance Method Evaluation Report from a Product Evaluation Entity
 
Evaluation Entity ICC Evaluation Service, LLC
Quality Assurance Entity ICC Evaluation Service, LLC (QA Entity)
Quality Assurance Contract Expiration Date 09/30/2027
Validated By ICC Evaluation Services, LLC
 
 
Certificate of Independence
 
Referenced Standard and Year (of Standard)
StandardYear
AAMA 14022009
ASTM E1362019
ASTM E330/330M-142021
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option C
 
Date Submitted 11/08/2023
Date Validated 11/27/2023
Date Pending FBC Approval
Date Approved 11/28/2023
 
Summary of Products
FL # Model, Number or Name Description
44502.1 7/8" Corrugated Exposed Fastener, Metal Wall Panels.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +0.0/-69.0
 Other: Positive Wind Loads Are Limited To The Capacity Of The Supporting Substrate And Framing.
Installation Instructions
 FL44502_R0_II_ESR-4730.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL44502_R0_AE_ESR-4730.pdf
44502.2 Narrow Groove Narrow Groove® - Narrow Width Metal Fascia, Soffit, And Wall Panel. 24GA Steel.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +0.0/-21
 Other: Positive Wind Loads Are Limited To The Capacity Of The Supporting Substrate And Framing.
Installation Instructions
 FL44502_R0_II_ESR-4730.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL44502_R0_AE_ESR-4730.pdf
44502.3 Narrow Groove Narrow Groove® - Narrow Width Metal Fascia, Soffit, And Wall Panel. .032" Aluminum
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +0.0/-10
 Other: Positive Wind Loads Are Limited To The Capacity Of The Supporting Substrate And Framing.
Installation Instructions
 FL44502_R0_II_ESR-4730.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL44502_R0_AE_ESR-4730.pdf
44502.4 Narrow Groove Narrow Groove® - Narrow Width Metal Fascia, Soffit, And Wall Panel. 20oz Copper.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +0.0/-17
 Other: Positive Wind Loads Are Limited To The Capacity Of The Supporting Substrate And Framing.
Installation Instructions
 FL44502_R0_II_ESR-4730.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL44502_R0_AE_ESR-4730.pdf
44502.5 PBR-Panel Exposed Fastener, Metal Wall Panel.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +0.0/-83
 Other: Positive Wind Loads Are Limited To The Capacity Of The Supporting Substrate And Framing.
Installation Instructions
 FL44502_R0_II_ESR-4730.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL44502_R0_AE_ESR-4730.pdf
44502.6 T-8 Plankwall Concealed Fastener Metal Siding Panel.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +0.0/-48
 Other: Positive Wind Loads Are Limited To The Capacity Of The Supporting Substrate And Framing.
Installation Instructions
 FL44502_R0_II_ESR-4730.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL44502_R0_AE_ESR-4730.pdf
44502.7 Western Lock Hidden Fastener, Standing Seam Metal Wall Panel
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +0.0/-76.0
 Other: Positive Wind Loads Are Limited To The Capacity Of The Supporting Substrate And Framing.
Installation Instructions
 FL44502_R0_II_ESR-4730.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL44502_R0_AE_ESR-4730.pdf
44502.8 Western Reveal Concealed Fastener, Metal Fascia, Soffit, And Wall Panels.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +0.0/-28
 Other: Positive Wind Loads Are Limited To The Capacity Of The Supporting Substrate And Framing.
Installation Instructions
 FL44502_R0_II_ESR-4730.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL44502_R0_AE_ESR-4730.pdf
44502.9 Western Rib Exposed Fastener, (7.2 Panel) Metal Wall Panel.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +0.0/-69.0
 Other: Positive Wind Loads Are Limited To The Capacity Of The Supporting Substrate And Framing.
Installation Instructions
 FL44502_R0_II_ESR-4730.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL44502_R0_AE_ESR-4730.pdf
44502.10 Western Wave Concealed Fastener, Metal Wall Panel. Installed Vertically or Horizontally.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +0.0/-76
 Other: Positive Wind Loads Are Limited To The Capacity Of The Supporting Substrate And Framing.
Installation Instructions
 FL44502_R0_II_ESR-4730.pdf
 Verified By: ICC Evaluation Service, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL44502_R0_AE_ESR-4730.pdf
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex