| 14645.1 |
2.5" Corrugated |
Min. 26 ga., 21.33" wide coverage through fastened roof panel over min. 19/32” thick plywood deck. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-86.0 Other: Uplift load of 86.0 psf at fastener spacing of 12" o.c. |
Installation Instructions FL14645_R6_II_EvaluationReportC3059_1.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL14645_R6_AE_EvaluationReportC3059_1.pdf Created by Independent Third Party: Yes |
|
|
| 14645.2 |
Classic Rib (1) |
Min. 29 ga., 36" wide through fastened roof panel over min. 15/32” thick plywood deck. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-91 Other: Uplift load of 91 psf at fastener spacing of 6" o.c. |
Installation Instructions FL14645_R6_II_EvaluationReportC3059_2.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL14645_R6_AE_EvaluationReportC3059_2.pdf Created by Independent Third Party: Yes |
|
|
| 14645.3 |
Classic Rib (2) |
Min. 26 ga., 36" wide through fastened roof panel over min. 19/32” thick plywood deck. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-133.9 Other: Uplift load of 133.9 psf at fastener spacing of 18" o.c. |
Installation Instructions FL14645_R6_II_EvaluationReportC3059_3.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL14645_R6_AE_EvaluationReportC3059_3.pdf Created by Independent Third Party: Yes |
|
|
| 14645.4 |
Classic Rib (3) |
Min. 29 ga., 36" wide through fastened roof panel over min. 7/16” thick OSB deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-135.0 Other: Uplift load of 135 psf at fastener spacing of 6" o.c. |
Installation Instructions FL14645_R6_II_EvaluationReportC3059_4.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL14645_R6_AE_EvaluationReportC3059_4.pdf Created by Independent Third Party: Yes |
|
|
| 14645.5 |
Classic Rib (4) |
Min. 29 ga., 36" wide through fastened roof panel over min. 15/32” thick plywood deck. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-138.5 Other: Uplift load of 138.5 psf at fastener spacing of 12" o.c. |
Installation Instructions FL14645_R6_II_EvaluationReportC3059_5.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL14645_R6_AE_EvaluationReportC3059_5.pdf Created by Independent Third Party: Yes |
|
|
| 14645.6 |
Magna-Loc |
Max. 16" wide, min. 24 ga. standing seam roof panel over plywood deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-166 Other: Uplift load of 166 psf @ MPW clip spacing of 12" o.c. |
Installation Instructions FL14645_R6_II_EvaluationReportC3059_6.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL14645_R6_AE_EvaluationReportC3059_6.pdf Created by Independent Third Party: Yes |
|
|
| 14645.7 |
Magna-Loc |
Max. 16" wide, min. 24 ga. standing seam roof panel over steel deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-168.5 Other: Uplift load of 168.5 psf @ MPW clip spacing of 12" o.c. |
Installation Instructions FL14645_R6_II_EvaluationReportC3059_7.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL14645_R6_AE_EvaluationReportC3059_7.pdf Created by Independent Third Party: Yes |
|
|
| 14645.8 |
PBR or R |
Min. 26 ga., 36" wide through fastened roof panel over min. 15/32” thick plywood deck. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-131.0 Other: Uplift load of 131.0 psf at fastener spacing of 6" o.c. |
Installation Instructions FL14645_R6_II_EvaluationReportC3059_8.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL14645_R6_AE_EvaluationReportC3059_8.pdf Created by Independent Third Party: Yes |
|
|
| 14645.9 |
Pro-Panel II |
Min. 29 ga., 36" wide through fastened roof panel over min. 15/32” thick plywood deck. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-71.5 Other: Uplift load of 71.5 psf at fastener spacing of 12" o.c. |
Installation Instructions FL14645_R6_II_EvaluationReportC3059_9.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL14645_R6_AE_EvaluationReportC3059_9.pdf Created by Independent Third Party: Yes |