14604.1 |
Series 1000 Non-Impact Aluminum SH |
Series 1000 Non-Impact Aluminum SH |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +45/-45 Other: |
Certification Agency Certificate FL14604_R6_C_CAC_NI006177.01-R4-signed.pdf FL14604_R6_C_CAC_NI006177.02-R2-signed.pdf Quality Assurance Contract Expiration Date 06/30/2020 Installation Instructions FL14604_R6_II_08-02477.pdf Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL14604_R6_AE_513233.pdf Created by Independent Third Party: Yes |
|
14604.2 |
Series 1431 Non-Impact Vinyl SH Nailing Fin |
Series 1431 Non-Impact Vinyl SH Nailing Fin |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Configuration: O/X Vent Size: W-44.38" H-35" Glazing: 3/4" Overall I.G. |
Certification Agency Certificate FL14604_R6_C_CAC_NI010607-R2-signed.pdf Quality Assurance Contract Expiration Date 12/31/2019 Installation Instructions FL14604_R6_II_08-00556B.pdf Verified By: Luis R. Lomas, P.E. Florida P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL14604_R6_AE_510945.pdf Created by Independent Third Party: Yes |
|
14604.3 |
Series 1441 Non-Impact Vinyl SH Flange |
Series 1441 Non-Impact Vinyl SH Flange |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Configuration: O/X Vent Size: W-50.38" H-35.13" Glazing: 3/4" Overall I.G. |
Certification Agency Certificate FL14604_R6_C_CAC_NI010813-R2-signed.pdf Quality Assurance Contract Expiration Date 04/30/2020 Installation Instructions FL14604_R6_II_08-00558B.pdf Verified By: Luis R. Lomas, P.E. Florida P.E. 61514 Created by Independent Third Party: Yes Evaluation Reports FL14604_R6_AE_510947A.pdf Created by Independent Third Party: Yes |
|
14604.4 |
Series 2451 Impact Vinyl SH Nailing Fin |
Series 2451 Impact Vinyl SH Nailing Fin |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Configuration: O/X Max. Frame Size: W-48" H-72" Max. Vent Size: W-44.25" H-35" Glazing: 3/4" Overall Laminated IG |
Certification Agency Certificate FL14604_R6_C_CAC_NI012533-R2.pdf Quality Assurance Contract Expiration Date 02/28/2022 Installation Instructions FL14604_R6_II_08-00562B.pdf Verified By: Luis R. Lomas, P.E. Florida P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL14604_R6_AE_510951.pdf Created by Independent Third Party: Yes |
|
14604.5 |
Series 2451 Impact Vinyl SH Nailing Fin |
Series 2451 Impact Vinyl SH Nailing Fin |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Configuration: O/X Max. Frame Size: W-48" H-72" Glazing: 3/4" Overall Laminated IG |
Certification Agency Certificate FL14604_R6_C_CAC_NI013364.02.pdf Quality Assurance Contract Expiration Date 09/30/2018 Installation Instructions FL14604_R6_II_08-02914.pdf Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL14604_R6_AE_513739.pdf Created by Independent Third Party: Yes |
|
14604.6 |
Series 2461 Impact Vinyl SH Flange |
Series 2461 Impact Vinyl SH Flange |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: O/X Max. Frame Size: W-53 1/8" H-72" Glazing: 3/4" Overall Laminated IG |
Certification Agency Certificate FL14604_R6_C_CAC_NI013364.03.pdf Quality Assurance Contract Expiration Date 09/30/2018 Installation Instructions FL14604_R6_II_08-02915.pdf Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL14604_R6_AE_513740.pdf Created by Independent Third Party: Yes |
|
14604.7 |
Series 2461 Impact Vinyl SH Flange |
Series 2461 Impact Vinyl SH Flange |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Configuration: O/X Vent Size: W-51" H-34.5" Glazing: 3/4" Overall Laminated IG |
Certification Agency Certificate FL14604_R6_C_CAC_NI012533.01-R3.pdf Quality Assurance Contract Expiration Date 02/28/2022 Installation Instructions FL14604_R6_II_08-00564B.pdf Verified By: Luis R. Lomas, P.E. Florida P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL14604_R6_AE_510953A.pdf Created by Independent Third Party: Yes |
|
14604.8 |
Series FWI 1000 Impact Aluminum SH |
Series FWI 1000 Impact Aluminum SH |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See drawing 08-02476 for design pressures.
GLASS INTERLAYER COMPLIES WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE ACCORDING TO MIAMI-DADE FOR EASTMAN INTERLAYERS |
Certification Agency Certificate FL14604_R6_C_CAC_NI009020.01-R2-signed.pdf FL14604_R6_C_CAC_NI009020.02-R1-signed.pdf FL14604_R6_C_CAC_NI009020.03-R2-signed.pdf FL14604_R6_C_CAC_NI010670.01-R1.pdf FL14604_R6_C_CAC_NI010670-R1-signed.pdf Quality Assurance Contract Expiration Date 12/31/2019 Installation Instructions FL14604_R6_II_08-02476A.pdf Verified By: Luis R. Lomas, P.E. Florida P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL14604_R6_AE_513232A.pdf Created by Independent Third Party: Yes |