14609.1 |
Series 143 Vinyl HVHZ Impact Casement with Nailing Fin or Flange |
Series 143 Vinyl HVHZ Impact Casement with Nailing Fin or Flange |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +70.0/-70.0 Other: Maximum size is 37" x 76". FRAME MATERIAL TO BE RIGID PVC FROM DECEUNINCK NORTH AMERICA AAMA CERTIFIED (DEP-1).
INTERLAYER COMPLIES WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE ACCORDING TO MIAMI-DADE FOR EASTMAN INTERLAYERS |
Certification Agency Certificate FL14609_R5_C_CAC_NI011284-R2.pdf Quality Assurance Contract Expiration Date 06/30/2021 Installation Instructions FL14609_R5_II_08-01779C.pdf Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL14609_R5_AE_512463C.pdf Created by Independent Third Party: Yes |
|
14609.2 |
Series 1631 Vinyl Non-Impact Casement with Nailing Fin |
Series 1631 Vinyl Non-Impact Casement with Nailing Fin |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Maximum size is 37" x 75". FRAME MATERIAL TO BE RIGID PVC FROM DECEUNINCK NORTH AMERICA AAMA CERTIFIED (DEP-1) |
Certification Agency Certificate FL14609_R5_C_CAC_NI010618-R2-signed.pdf Quality Assurance Contract Expiration Date 04/30/2020 Installation Instructions FL14609_R5_II_08-00561B.pdf Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL14609_R5_AE_510950.pdf Created by Independent Third Party: Yes |
|
14609.3 |
Series 1641 Vinyl Non-Impact Casement with Flange |
Series 1641 Vinyl Non-Impact Casement with Flange |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Maximum size is 37" x 75". FRAME MATERIAL TO BE RIGID PVC FROM DECEUNINCK NORTH AMERICA AAMA CERTIFIED (DEP-1) |
Certification Agency Certificate FL14609_R5_C_CAC_NI010618.01-R2-signed.pdf Quality Assurance Contract Expiration Date 04/30/2020 Installation Instructions FL14609_R5_II_08-00700B.pdf Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL14609_R5_AE_511113A.pdf Created by Independent Third Party: Yes |
|
14609.4 |
Series 2651 Vinyl Impact Casement with Nailing Fin |
Series 2651 Vinyl Impact Casement with Nailing Fin |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Maximum size is 37" x 75". FRAME MATERIAL TO BE RIGID PVC FROM DECEUNINCK NORTH AMERICA AAMA CERTIFIED (DEP-1) |
Certification Agency Certificate FL14609_R5_C_CAC_NI010618-R2-signed.pdf FL14609_R5_C_CAC_NI010631-R2-signed.pdf Quality Assurance Contract Expiration Date 04/30/2020 Installation Instructions FL14609_R5_II_08-00567B.pdf Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL14609_R5_AE_510956.pdf Created by Independent Third Party: Yes |
|
14609.5 |
Series 2661 Vinyl Impact Casement with Flange |
Series 2661 Vinyl Impact Casement with Flange |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: Maximum size is 37" x 75". FRAME MATERIAL TO BE RIGID PVC FROM DECEUNINCK NORTH AMERICA AAMA CERTIFIED (DEP-1) |
Certification Agency Certificate FL14609_R5_C_CAC_NI010618.01-R2-signed.pdf FL14609_R5_C_CAC_NI010676-R2-signed.pdf Quality Assurance Contract Expiration Date 04/30/2020 Installation Instructions FL14609_R5_II_08-00568B.pdf Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL14609_R5_AE_510957A.pdf Created by Independent Third Party: Yes |