| 14668.1 |
1 - "Series 2500" Steel |
24 gauge steel roof panel attached to 16 gauge Steel Purlins with mechanically seamed floating panel clips |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-78 max. Other: Refer to Evaluation Report for Conditions and Limits of Use. Refer to manufacturer's installations instructions as a supplemental guide. |
Installation Instructions FL14668_R6_II_1_S2500_24ga_SteelPurlins_EVALREPORT_.pdf Verified By: James L. Buckner, P.E. @ CBUCK, Inc P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL14668_R6_AE_1_S2500_24ga_SteelPurlins_EVALREPORT_.pdf Created by Independent Third Party: Yes |
|
|
| 14668.2 |
2 - "Series 2500" Aluminum |
0.040" Aluminum roof panel attached to 16 gauge Steel Purlins with mechanically seamed floating panel clips |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-120max. Other: Refer to Evaluation Report for Conditions and Limits of Use. Refer to manufacturer's installations instructions as a supplemental guide. |
Installation Instructions FL14668_R6_II_2_S2500_040Alum_SteelPurlins_EVALREPORT_.pdf Verified By: James L. Buckner, P.E. @ CBUCK, Inc P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL14668_R6_AE_2_S2500_040Alum_SteelPurlins_EVALREPORT_.pdf Created by Independent Third Party: Yes |
|
|
| 14668.3 |
3 - "Series 3000" Steel |
“Series 3000” Standing Seam Roof Panel
2-3/4” Rib Height, 15-1/4” wide, 24 gauge steel roof panel attached to 16 gauge Steel Purlins with mechanically seamed fixed panel clips, batten caps and adhesive.
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-90 Other: Refer to Evaluation Report for Conditions and Limits of Use. Refer to manufacturer's installations instructions as a supplemental guide. |
Installation Instructions FL14668_R6_II_3_S3000_24ga_SteelPurlins_EVALREPORT_.pdf Verified By: James L. Buckner, P.E. @ CBUCK, Inc P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL14668_R6_AE_3_S3000_24ga_SteelPurlins_EVALREPORT_.pdf Created by Independent Third Party: Yes |
|
|
| 14668.4 |
4 - "Series 3000" Aluminum |
“Series 3000” Standing Seam Roof Panel
2-3/4” Rib Height, 15-1/4” wide, 0.037” Aluminum roof panel attached to 16 gauge Steel Purlins with mechanically seamed fixed panel clips, batten caps and adhesive.
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-110 Other: Refer to Evaluation Report for Conditions and Limits of Use. Refer to manufacturer's installations instructions as a supplemental guide. |
Installation Instructions FL14668_R6_II_4_S3000_037Alum_SteelPurlins_EVALREPORT_.pdf Verified By: James L. Buckner, P.E. @ CBUCK, Inc P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL14668_R6_AE_4_S3000_037Alum_SteelPurlins_EVALREPORT_.pdf Created by Independent Third Party: Yes |