| 14603.1 |
Non-Impact Wood Mullion |
1" x 5.59" Wood Mullion |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: Mullion size, pressure, assembly and installation requirements are to be as specified in the attached drawing No. 1442. Job required design wind pressure shall be calculated in accordance with the Florida Building Code Chapter 16 and ASCE 7 Minimum Design Loads for Buildings and Other Structures. |
Installation Instructions FL14603_R6_II_Drawing 1442.pdf Verified By: Warren W. Schaefer FL PE 44135 Created by Independent Third Party: Yes Evaluation Reports FL14603_R6_AE_Evaluation report WWS-188.pdf Created by Independent Third Party: Yes |
|
|
| 14603.2 |
Non-Impact Wood Mullion |
1" x 7.56" Wood Mullion |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: Mullion size, pressure, assembly and installation requirements are to be as specified in the attached drawing No. 1443. Job required design wind pressure shall be calculated in accordance with the Florida Building Code Chapter 16 and ASCE 7 Minimum Design Loads for Buildings and Other Structures. |
Installation Instructions FL14603_R6_II_Drawing 1443.pdf Verified By: Warren W. Schaefer FL PE 44135 Created by Independent Third Party: Yes Evaluation Reports FL14603_R6_AE_Evaluation report WWS-189.pdf Created by Independent Third Party: Yes |
|
|
| 14603.3 |
Non-Impact Wood Mullion |
1" x 4.45" Wood Mullion |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: Mullion size, pressure, assembly and installation requirements are to be as specified in the attached drawing No. 1444. Job required design wind pressure shall be calculated in accordance with the Florida Building Code Chapter 16 and ASCE 7 Minimum Design Loads for Buildings and Other Structures. |
Installation Instructions FL14603_R6_II_Drawing 1444.pdf Verified By: Warren W. Schaefer FL PE 44135 Created by Independent Third Party: Yes Evaluation Reports FL14603_R6_AE_Evaluation report WWS-190.pdf Created by Independent Third Party: Yes |
|
|
| 14603.4 |
Non-Impact Wood Mullion |
1" x 6.42" Wood Mullion |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: Mullion size, pressure, assembly and installation requirements are to be as specified in the attached drawing No. 1445. Job required design wind pressure shall be calculated in accordance with the Florida Building Code Chapter 16 and ASCE 7 Minimum Design Loads for Buildings and Other Structures. |
Installation Instructions FL14603_R6_II_Drawing 1445.pdf Verified By: Warren W. Schaefer FL PE 44135 Created by Independent Third Party: Yes Evaluation Reports FL14603_R6_AE_Evaluation report WWS_191.pdf Created by Independent Third Party: Yes |