14632.1 |
10300085 Aluminum Impact Resistant |
X-Mullion (Reinforced) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See drawing 08-00810A for design pressure rating table and allowable sizes & configurations. Mullion is rated impact resistant for Wind Zone 3 or Less |
Installation Instructions FL14632_R3_II_08-00810A.pdf Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL14632_R3_AE_511354A.pdf Created by Independent Third Party: Yes |
|
14632.2 |
10300085 Aluminum Impact Resistant |
X-Mullion (Non-Reinforced) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See drawing 08-00807A for design pressure rating table and allowable sizes & configurations. Mullion is rated impact resistant for Wind Zone 3 or Less |
Installation Instructions FL14632_R3_II_08-00807A.pdf Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL14632_R3_AE_511351A.pdf Created by Independent Third Party: Yes |
|
14632.3 |
10300085 Aluminum Impact Resistant |
T-Mullion (Reinforced) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See drawing 08-00809A for design pressure rating table and allowable sizes & configurations. Mullion is rated impact resistant for Wind Zone 3 or Less |
Installation Instructions FL14632_R3_II_08-00809A.pdf Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL14632_R3_AE_511353A.pdf Created by Independent Third Party: Yes |
|
14632.4 |
10300085 Aluminum Impact Resistant |
Horizontal Mullion (Non-Reinforced) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See drawing 08-00806A for design pressure rating table and allowable sizes & configurations. Mullion is rated impact resistant for Wind Zone 3 or Less |
Installation Instructions FL14632_R3_II_08-00806A.pdf Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL14632_R3_AE_511350A.pdf Created by Independent Third Party: Yes |
|
14632.5 |
10300085 Aluminum Impact Resistant |
Vertical Mullion (Reinforced) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See drawing 08-00808A for design pressure rating table and allowable sizes & configurations. Mullion is rated impact resistant for Wind Zone 3 or Less |
Installation Instructions FL14632_R3_II_08-00808A.pdf Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL14632_R3_AE_511352A.pdf Created by Independent Third Party: Yes |
|
14632.6 |
10300085 Aluminum Impact Resistant |
Vertical Mullion (Non-Reinforced) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: See drawing 08-00805A for design pressure rating table and allowable sizes & configurations. Mullion is rated impact resistant for Wind Zone 3 or Less |
Installation Instructions FL14632_R3_II_08-00805A.pdf Verified By: Luis R. Lomas, P.E. 62514 Created by Independent Third Party: Yes Evaluation Reports FL14632_R3_AE_511349A.pdf Created by Independent Third Party: Yes |