| 6252.1 |
24 Ga. SMS 416 |
24 Ga. SMS 416 16" Wide Roof Panel over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-104.3psf Other: -104.3 psf @ 12” O.C. Clip Spacing. -54.3 psf @ 30” O.C. Clip Spacing. Install per manufacturers instructions. Not for use in HVHZ Zones. |
Installation Instructions FL6252_R8_II_SMS 416 24 Ga. over Plywood.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL6252_R8_AE_SMS 416 24 Ga. over Plywood.pdf Created by Independent Third Party: Yes |
|
|
| 6252.2 |
26 Ga. Superior Rib Panel |
26 Ga. Superior Rib Panel over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-78.5 psf Other: -78.5 psf @ 24” O.C. Fastener Spacing. Install per manufacturers instructions. Not for use in HVHZ Zones. |
Installation Instructions FL6252_R8_II_26 Ga. Superior Rib over Plywood.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL6252_R8_AE_26 Ga. Superior Rib over Plywood.pdf Created by Independent Third Party: Yes |