| 8384.1 |
PBR Panel |
26 Ga. PBR Roof Panel over open framing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +60.0PSF/-47.5PSF Other: +60.0 psf @ 5'-0" o.c. / -47.5 psf @ 5'-0" o.c. fastener spacing. Install per manufacturers details.in compliance with CURRENT FBC .
Not for use in HVHZ Zones. |
Installation Instructions FL8384_R6_II_RSS n2023 FL 8384 REPORTS AND DETAILS MARLYN METALS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL8384_R6_AE_RSS n2023 FL 8384 REPORTS AND DETAILS MARLYN METALS.pdf Created by Independent Third Party: Yes |
|
|
| 8384.2 |
PBR Panel |
24 Ga. PBR Roof Panel over open framing
|
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +N/A/-150.0PSF Other: -60.0 psf @ 5'-0" o.c. fastener pattern of 12"-12"- 12". -150.0 psf @ 2'-0" o.c. fastener pattern 12"-12"-12". Install per manufacturers details, in compliance with CURRENT FBC . For use in HVHZ Zones. |
Installation Instructions FL8384_R6_II_RSS n2023 FL 8384 REPORTS AND DETAILS MARLYN METALS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL8384_R6_AE_RSS n2023 FL 8384 REPORTS AND DETAILS MARLYN METALS.pdf Created by Independent Third Party: Yes |
|
|
| 8384.3 |
R or PBR Roof Panel |
26 Ga. R or PBR Roof Panel over open framing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-52.5psf Other: -52.5 psf. Fastener pattern 7"-5"-7"-5" 7" @ 5'-0" o.c. Install per manufacturers details, in compliance with CURRENT FBC .
Not for use in HVHZ Zones. |
Installation Instructions FL8384_R6_II_RSS n2023 FL 8384 REPORTS AND DETAILS MARLYN METALS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL8384_R6_AE_RSS n2023 FL 8384 REPORTS AND DETAILS MARLYN METALS.pdf Created by Independent Third Party: Yes |
|
|
| 8384.4 |
R or PBR Roof Panel |
26 Ga. R or PBR Roof Panel over open framing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-52.5psf Other: -52.5 psf fastener pattern of 12"-12"-12" @ 5'-0" o.c. Install per manufacturers details, in compliance with CURRENT FBC . Not for use in HVHZ Zones. |
Installation Instructions FL8384_R6_II_RSS n2023 FL 8384 REPORTS AND DETAILS MARLYN METALS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL8384_R6_AE_RSS n2023 FL 8384 REPORTS AND DETAILS MARLYN METALS.pdf Created by Independent Third Party: Yes |