| 47382.1 |
CMP Multi-Rib Roof Panel |
29 ga X 36" wide |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +n/a/-56.0 Other: Per UL580/1897 Test over 15/32" Plywood w/ 4 fasteners per panel at 24" o.c. with Safety Factor of 2.0 |
Installation Instructions FL47382_R0_II_T377-20.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL47382_R0_TR_T377-20.pdf |
|
|
| 47382.2 |
CMP Multi-Rib Roof Panel |
29 ga X 36" wide |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +n/a/-73.5 Other: Per UL580/1897 Test over 15/32" plywood w/ 4 fasteners per panel at 6" o.c. with Safety Factor of 2.0 |
Installation Instructions FL47382_R0_II_T377-20.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL47382_R0_TR_T377-20.pdf |
|
|
| 47382.3 |
CMP Multi-Rib Roof Panel |
29 ga X 36" wide |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +n/a/-161.9 Other: Per UL580/1897 test over 15/32" Plywood w/ 5 fasteners per panel at 6" o.c. with Safety Factor of 2.0 |
Installation Instructions FL47382_R0_II_T377-20.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL47382_R0_TR_T377-20.pdf |
|
|
| 47382.4 |
CMP Multi-Rib Roof Panel |
26 ga X 36" wide |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +n/a/-86.0 Other: Per UL580/1897 Test over 15/32" Plywood w/ 5 fasteners per panel at 24" o.c. with Safety Factor of 2.0 |
Installation Instructions FL47382_R0_II_T379-20.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL47382_R0_TR_T379-20.pdf |
|
|
| 47382.5 |
CMP Multi-Rib Roof Panel |
26 ga X 36" wide |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +n/a/-161.4 Other: Per UL580/1897 Test over 15/32" Plywood w/ 5 fasteners per panel at 6" o.c. with Safety Factor of 2.0 |
Installation Instructions FL47382_R0_II_T379-20.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL47382_R0_TR_T379-20.pdf |
|
|
| 47382.6 |
CMP Series Nail Strip |
26 ga X 16" wide |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +n/a/-41.6 Other: Per UL580 Test over 15/32" Plywood w/ fasteners at 4-1/2" o.c. with Safety Factor of 2.0 |
Installation Instructions FL47382_R0_II_T107-21.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL47382_R0_TR_T107-21.pdf |
|
|
| 47382.7 |
CMP Series Nail Strip |
26 ga X 16" wide |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +n/a/-39.8 Other: Per UL580 Test over 15/32" Plywood w/ fasteners at 18-1/2" o.c. with Safety Factor of 2.0 |
Installation Instructions FL47382_R0_II_T107-21.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL47382_R0_TR_T107-21.pdf |
|
|
| 47382.8 |
CMP Series Nail Strip |
0.032" Aluminum X 16" Wide |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +n/a/-26.75 Other: Per UL580 Test over 15/32" Plywood w/ fasteners at 18-1/2" o.c. with Safety Factor of 2.0 |
Installation Instructions FL47382_R0_II_T108-21.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL47382_R0_TR_T108-21.pdf |
|
|
| 47382.9 |
CMP Series Nail Strip |
0.032" Aluminum X 16" Wide |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +n/a/-41.6 Other: per UL580 Test over 15/32" Plywood w/ fasteners at 4-1/2" o.c. with Safety Factor of 2.0 |
Installation Instructions FL47382_R0_II_T108-21.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL47382_R0_TR_T108-21.pdf |
|
|
| 47382.10 |
CMP Series Nail Strip |
26 ga X 16" wide |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +n/a/-52.8 Other: Per UL580/1897 Test over 15/32" Plywood w/ fasteners at 4-1/2" o.c. w/ structural adhesive with Safety Factor of 2.0 |
Installation Instructions FL47382_R0_II_T133-21.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL47382_R0_TR_T133-21.pdf |
|
|
| 47382.11 |
CMP Series Nail Strip |
0.032" Aluminum X 16" Wide |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +n/a/-52.5 Other: Per UL580 Test over 15/32" Plywood w/ fasteners at 4-1/2" o.c. w/ structural adhesive with Safety factor of 2.0 |
Installation Instructions FL47382_R0_II_T134-21.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL47382_R0_TR_T134-21.pdf |