FL # FL47359
Application Type New
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Permasteelisa North America Corp.
Address/Phone/Email 1179 Center Point Boulevard
Mondota Heights, MN 55120
(514) 245-3147
levin.yao@permasteelisagroup.com
 
Authorized Signature Yiping Wang
mcyengineering@outlook.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Panel Walls
Subcategory Curtain Walls
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Yiping Wang
Florida License PE-55983
Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity
Quality Assurance Contract Expiration Date 12/31/2026
Validated By Xiaojun Gu
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL47359_R0_COI_Certificate of Independence-SS.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
AAMA 5012015
TAS 2011994
TAS 2021994
TAS 2031994
 
Equivalence of Product Standards
Certified By

Florida Licensed Professional Engineer or Architect
FL47359_R0_Equiv_Equivalence of Standards EWS-101 EWS-401 ss.pdf
FL47359_R0_Equiv_Equivalence of Standards EWS101-ss.pdf
FL47359_R0_Equiv_Equivalence of Standards EWS102 SS.pdf
FL47359_R0_Equiv_Equivalence of Standards EWS-103 ss.pdf
FL47359_R0_Equiv_Equivalence of Standards EWS104 SS.pdf
FL47359_R0_Equiv_Equivalence of Standards EWS401 ss.pdf
 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 02/26/2025
Date Validated 11/10/2025
Date Pending FBC Approval 11/15/2025
Date Approved 02/10/2026
 
Summary of Products
FL # Model, Number or Name Description
47359.1 CURTAIN WALL SYSTEM - LMI EWS-104 CURTAIN WALL SYSTEM - LMI
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +65/-100
 Other:  
Installation Instructions
 FL47359_R0_II_EWS-104 CURTAIN WALL SYSTEM - LMI FL47359.1 AD25-06 R11.03.2025 - ss.pdf
 Verified By: Yiping Wang PE #55983
 Created by Independent Third Party: Yes
Evaluation Reports
 FL47359_R0_AE_Evaluation Report EWS104 SS.pdf
 Created by Independent Third Party: Yes
47359.2 CURTAIN WALL SYSTEM - SMI EWS-101&EWS-104 CURTAIN WALL SYSTEM - SMI
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +70/-100
 Other:  
Installation Instructions
 FL47359_R0_II_EWS-101 EWS-401 CURTAIN WALL SYSTEM-SMI FL47359.2 R11.03.2025 - ss.pdf
 Verified By: Yiping Wang PE #55983
 Created by Independent Third Party: Yes
Evaluation Reports
 FL47359_R0_AE_Evaluation Report EWS-101 EWS-401.pdf
 Created by Independent Third Party: Yes
47359.3 CURTAIN WALL SYSTEM - SMI EWS-103 CURTAIN WALL SYSTEM-SMI
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +71/-95
 Other:  
Installation Instructions
 FL47359_R0_II_EWS-103 CURTAIN WALL SYSTEM-SMI FL47359.3 R11.03.2025 ss.pdf
 Verified By: Yiping Wang PE #55983
 Created by Independent Third Party: Yes
Evaluation Reports
 FL47359_R0_AE_Evaluation Report EWS-103.pdf
 Created by Independent Third Party: Yes
47359.4 CURTAIN WALL SYSTEM-LMI EWS-102 GLASS CURTAIN WALL SYSTEM-LMI
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +60/-75
 Other:  
Installation Instructions
 FL47359_R0_II_EWS-102 GLASS CURTAIN WALL SYSTEM FL47359.4 AD25-07 R 11.03.2025 - ss.pdf
 Verified By: Yiping Wang PE #55983
 Created by Independent Third Party: Yes
Evaluation Reports
 FL47359_R0_AE_Evaluation Report EWS102 SS.pdf
 Created by Independent Third Party: Yes
47359.5 CURTAIN WALL SYSTEM-LMI EWS-401 GLASS CURTAIN WALL SYSTEM-LMI
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +70/-79
 Other:  
Installation Instructions
 FL47359_R0_II_EWS-401 SLANTED ALUMINUM CURTAIN WALL LMI FL47359.5 R11.03.2025 - ss.pdf
 Verified By: Yiping Wang PE #55983
 Created by Independent Third Party: Yes
Evaluation Reports
 FL47359_R0_AE_Evaluation Report EWS401.pdf
 Created by Independent Third Party: Yes
47359.6 CURTAIN WALL SYSTEM-SMI EWS-101 CURTAIN WALL SYSTEM-SMI
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +68/-72
 Other:  
Installation Instructions
 FL47359_R0_II_(PMU08) EWS-101 CURTAIN WALL SYSTEM SMALL MISSILE IMPACT FL47359.6 R 11.03.2025 - ss.pdf
 Verified By: Yiping Wang PE #55983
 Created by Independent Third Party: Yes
Evaluation Reports
 FL47359_R0_AE_Evaluation Report EWS101-ss.pdf
 Created by Independent Third Party: Yes
47359.7 CURTAIN WALL SYSTEM-SMI EWS-101 CURTAIN WALL SYSTEM-SMI
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +68/-86
 Other:  
Installation Instructions
 FL47359_R0_II_(PMU09) EWS-101 CURTAIN WALL SYSTEM (PEAK AREA) SMALL MISSILE IMPACT FL47359.7 R11.03.2025 - ss.pdf
 Verified By: Yiping Wang PE #55983
 Created by Independent Third Party: Yes
Evaluation Reports
 FL47359_R0_AE_Evaluation Report EWS101-ss.pdf
 Created by Independent Third Party: Yes
 