Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL47356
Application Type New
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Elite Metal Manufacturing, LLC
Address/Phone/Email 10121 88th Trace
Live Oak, FL 32064
(386) 688-3627
kyle@lawyerkyle.com
 
Authorized Signature Kyle McLeod
kyle@lawyerkyle.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Roofing
Subcategory Metal Roofing
 
Compliance Method Test Report
 
Testing Lab Farabaugh Engineering and Testing, LLC
Quality Assurance Entity Farabaugh Engineering and Testing, LLC
Quality Assurance Contract Expiration Date 03/25/2031
Validated By Steven M. Urich, PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL47356_R0_COI_FL39466_R1_COI_FETCOIElite.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM E1592-052017
 
Equivalence of Product Standards
Certified By

 
 
 
 
Product Approval Method Method 1 Option B
 
Date Submitted 02/24/2025
Date Validated 02/26/2025
Date Pending FBC Approval 02/27/2025
Date Approved 04/15/2025
 
Summary of Products
FL # Model, Number or Name Description
47356.1 Elite Rib Roof Panel 26 ga Elite Rib Roof Panel Over Open Framing
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +41.65/-41.65
 Other: Per ASTM E1592 Test over 14 ga open framing supports located at 4' on centers with safety factor of 2.0
Installation Instructions
 FL47356_R0_II_T298-24-Elite.pdf
 Verified By: Farabaugh Engineering and Testing, LLC
Test Reports
 FL47356_R0_TR_T298-24-Elite.pdf
47356.2 Elite Rib Roof Panel 29 ga Elite Rib Roof Panel Over Open Framing
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +20.8/-23.4
 Other: Per ASTM E1592 Test over 14 ga open framing supports located at 5' on centers with safety factor of 2.0
Installation Instructions
 FL47356_R0_II_T292-24-Elite.pdf
 Verified By: Farabaugh Engineering and Testing, LLC
Test Reports
 FL47356_R0_TR_T292-24-Elite.pdf
47356.3 Elite Rib Roof Panel 29 ga Elite Rib Roof Panel Over Open Framing
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +36.4/-33.8
 Other: Per ASTM E1592 Test over 14 ga open framing supports located at 4' on centers with safety factor of 2.0
Installation Instructions
 FL47356_R0_II_T294-24-Elite.pdf
 Verified By: Farabaugh Engineering and Testing, LLC
Test Reports
 FL47356_R0_TR_T294-24-Elite.pdf
47356.4 Elite Rib Roof Panel 26 ga Elite Rib Roof Panel Over Open Framing
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +23.4/-28.6
 Other: Per ASTM E1592 Test over 14 ga open framing supports located at 5' on centers with safety factor of 2.0
Installation Instructions
 FL47356_R0_II_T296-24-Elite.pdf
 Verified By: Farabaugh Engineering and Testing, LLC
Test Reports
 FL47356_R0_TR_T296-24-Elite.pdf
47356.5 Elite Rib Roof Panel 29 ga Elite Rib Roof Panel Over Open Framing
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +36.4/-33.8
 Other: Per ASTM E1592 Test over 18 ga hat channel 4' on centers with safety factor of 2.0
Installation Instructions
 FL47356_R0_II_T300-24-Elite.pdf
 Verified By: Farabaugh Engineering and Testing, LLC
Test Reports
 FL47356_R0_TR_T300-24-Elite.pdf
47356.6 Elite Rib Roof Panel 29 ga Elite Rib Roof Panel Over Open Framing
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +75.4/-54.6
 Other: Per ASTM E1592 Test over 18 ga hat channel 3' on centers with safety factor of 2.0
Installation Instructions
 FL47356_R0_II_T302-24-Elite.pdf
 Verified By: Farabaugh Engineering and Testing, LLC
Test Reports
 FL47356_R0_TR_T302-24-Elite.pdf
47356.7 Elite Rib Roof Panel 29 ga Elite Rib Roof Panel Over Open Framing
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +197.75/-93.6
 Other: Per ASTM E1592 Test over 18 ga hat channel 2' on centers with safety factor of 2.0
Installation Instructions
 FL47356_R0_II_T304-24-Elite.pdf
 Verified By: Farabaugh Engineering and Testing, LLC
Test Reports
 FL47356_R0_TR_T304-24-Elite.pdf
47356.8 Elite Rib Roof Panel 26 ga Elite Rib Roof Panel Over Open Framing
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +39/-39
 Other: Per ASTM E1592 Test over 18 ga hat channel 4' on centers with safety factor of 2.0
Installation Instructions
 FL47356_R0_II_T306-24-Elite.pdf
 Verified By: Farabaugh Engineering and Testing, LLC
Test Reports
 FL47356_R0_TR_T306-24-Elite.pdf
47356.9 Elite Rib Roof Panel 26 ga Elite Rib Roof Panel Over Open Framing
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +80.6/-62.4
 Other: Per ASTM E1592 Test over 18 ga hat channel 3' on centers with safety factor of 2.0
Installation Instructions
 FL47356_R0_II_T308-24-Elite.pdf
 Verified By: Farabaugh Engineering and Testing, LLC
Test Reports
 FL47356_R0_TR_T308-24-Elite.pdf
47356.10 Elite Rib Roof Panel 26 ga Elite Rib Roof Panel Over Open Framing
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +200.2/-91
 Other: Per ASTM E1592 Test over 18 ga hat channel 2' on centers with safety factor of 2.0
Installation Instructions
 FL47356_R0_II_T310-24-Elite.pdf
 Verified By: Farabaugh Engineering and Testing, LLC
Test Reports
 FL47356_R0_TR_T310-24-Elite.pdf
 
Back   Next
 