| 47356.1 |
Elite Rib Roof Panel |
26 ga Elite Rib Roof Panel Over Open Framing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +41.65/-41.65 Other: Per ASTM E1592 Test over 14 ga open framing supports located at 4' on centers with safety factor of 2.0 |
Installation Instructions FL47356_R0_II_T298-24-Elite.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL47356_R0_TR_T298-24-Elite.pdf |
|
|
| 47356.2 |
Elite Rib Roof Panel |
29 ga Elite Rib Roof Panel Over Open Framing
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +20.8/-23.4 Other: Per ASTM E1592 Test over 14 ga open framing supports located at 5' on centers with safety factor of 2.0 |
Installation Instructions FL47356_R0_II_T292-24-Elite.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL47356_R0_TR_T292-24-Elite.pdf |
|
|
| 47356.3 |
Elite Rib Roof Panel |
29 ga Elite Rib Roof Panel Over Open Framing
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +36.4/-33.8 Other: Per ASTM E1592 Test over 14 ga open framing supports located at 4' on centers with safety factor of 2.0 |
Installation Instructions FL47356_R0_II_T294-24-Elite.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL47356_R0_TR_T294-24-Elite.pdf |
|
|
| 47356.4 |
Elite Rib Roof Panel |
26 ga Elite Rib Roof Panel Over Open Framing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +23.4/-28.6 Other: Per ASTM E1592 Test over 14 ga open framing supports located at 5' on centers with safety factor of 2.0 |
Installation Instructions FL47356_R0_II_T296-24-Elite.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL47356_R0_TR_T296-24-Elite.pdf |
|
|
| 47356.5 |
Elite Rib Roof Panel |
29 ga Elite Rib Roof Panel Over Open Framing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +36.4/-33.8 Other: Per ASTM E1592 Test over 18 ga hat channel 4' on centers with safety factor of 2.0 |
Installation Instructions FL47356_R0_II_T300-24-Elite.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL47356_R0_TR_T300-24-Elite.pdf |
|
|
| 47356.6 |
Elite Rib Roof Panel |
29 ga Elite Rib Roof Panel Over Open Framing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +75.4/-54.6 Other: Per ASTM E1592 Test over 18 ga hat channel 3' on centers with safety factor of 2.0 |
Installation Instructions FL47356_R0_II_T302-24-Elite.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL47356_R0_TR_T302-24-Elite.pdf |
|
|
| 47356.7 |
Elite Rib Roof Panel |
29 ga Elite Rib Roof Panel Over Open Framing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +197.75/-93.6 Other: Per ASTM E1592 Test over 18 ga hat channel 2' on centers with safety factor of 2.0 |
Installation Instructions FL47356_R0_II_T304-24-Elite.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL47356_R0_TR_T304-24-Elite.pdf |
|
|
| 47356.8 |
Elite Rib Roof Panel |
26 ga Elite Rib Roof Panel Over Open Framing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +39/-39 Other: Per ASTM E1592 Test over 18 ga hat channel 4' on centers with safety factor of 2.0 |
Installation Instructions FL47356_R0_II_T306-24-Elite.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL47356_R0_TR_T306-24-Elite.pdf |
|
|
| 47356.9 |
Elite Rib Roof Panel |
26 ga Elite Rib Roof Panel Over Open Framing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +80.6/-62.4 Other: Per ASTM E1592 Test over 18 ga hat channel 3' on centers with safety factor of 2.0 |
Installation Instructions FL47356_R0_II_T308-24-Elite.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL47356_R0_TR_T308-24-Elite.pdf |
|
|
| 47356.10 |
Elite Rib Roof Panel |
26 ga Elite Rib Roof Panel Over Open Framing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +200.2/-91 Other: Per ASTM E1592 Test over 18 ga hat channel 2' on centers with safety factor of 2.0 |
Installation Instructions FL47356_R0_II_T310-24-Elite.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL47356_R0_TR_T310-24-Elite.pdf |