| 9903.1 |
Mechanical Lock 2" |
2" Mechanical Lock, 24 Ga. 16" Wide Roof Panel over open framing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-83.8 psf Other: -36.0 psf at 5'-0" o.c. clip spacing. -83.8 psf at 2'-0" o.c. clip spacing. Install per manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL9903_R7_II_2 in Mechanical Lock Structural Roof Panel NON HVHZ.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL9903_R7_AE_2 in Mechanical Lock Structural Roof Panel NON HVHZ.pdf Created by Independent Third Party: Yes |
|
|
| 9903.2 |
PBR Roof Panel |
26 Ga. PBR Roof Panel over open framing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +55.0PSF/-45.0psf Other: -45.0 psf / +55.0 psf @ 5’-0” o.c. Fastener Spacing. Install per manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL9903_R7_II_26 Ga. PBR Structural Roof Panel.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL9903_R7_AE_26 Ga. PBR Structural Roof Panel.pdf Created by Independent Third Party: Yes |
|
|
| 9903.3 |
Ultra-Rib Roof Panel |
29 Ga. Ultra-Rib Panel over open framing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +26.0 psf/-31.2 psf Other: -31.2 psf / +26.0 psf at 5'-0" o.c. fastener spacing. Install per manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL9903_R7_II_29 Ga. Ultra Rib Roof Panel.pdf Verified By: Johnathan E Green, P.E. 88223 Created by Independent Third Party: Yes Evaluation Reports FL9903_R7_AE_29 Ga. Ultra Rib Roof Panel.pdf Created by Independent Third Party: Yes |