| 12718.1 |
26 Ga. PBR |
26 Ga. PBR Roof Panel over 19/32” Plywood |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-154.7PSF Other: -60.5 psf at 12”-12”-12” Fastener Pattern at 24” O.C. Fastener Spacing. -154.75 psf at 7”-5”-7”-5”-7” Fastener Pattern at 12” O.C. Fastener Spacing 15/32"plywood over existing and 19/32" for new construction in HVHZ ZONES.
INSTALL per manufacturer details and RAS 133. For use in HVHZ Zones. |
Installation Instructions FL12718_R5_II_SS FL 12718 REPORT AND INSTALL DETAILS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL12718_R5_AE_SS FL 12718 REPORT AND INSTALL DETAILS.pdf Created by Independent Third Party: Yes |
|
|
| 12718.2 |
26 Ga. PBR |
26 Ga. PBR Roof Panel over SYP 1 x 4 Wood Purlins |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-100.5PSF Other: -100.5 psf at 12”-12”-12” Fastener Pattern at 24” O.C. Fastener Spacing. -151.75 psf at 7”-5”-7”-5”-7” Fastener Pattern at 12” O.C. Fastener Spacing. SYP 1x4 thru fastened over CDX 15/32"plywood. Install per manufacturers details and RAS 133. For use in HVHZ Zones. |
Installation Instructions FL12718_R5_II_SS FL 12718 REPORT AND INSTALL DETAILS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL12718_R5_AE_SS FL 12718 REPORT AND INSTALL DETAILS.pdf Created by Independent Third Party: Yes |
|
|
| 12718.3 |
26 Ga. Rib |
26 Ga. Rib over 15/32" Plywood- B-C 4 PLY |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-146.0PSF Other: -69.25 psf @ 2’-0” O.C. Fastener Pattern Type A. -146.0 psf @ 1’-0” O.C. Fastener Pattern Type B. Install per manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL12718_R5_II_SS FL 12718 REPORT AND INSTALL DETAILS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL12718_R5_AE_SS FL 12718 REPORT AND INSTALL DETAILS.pdf Created by Independent Third Party: Yes |
|
|
| 12718.4 |
29 Ga. Rib |
29 Ga. Rib over 15/32" Plywood B-C 4 PLY |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-146.0PSF Other: -67.75 psf @ 2’-0” O.C. Fastener Pattern Type A. -146.0 psf @ 1’-0” O.C. Fastener Pattern Type B. Install per manufacturer's details. Not for use in HVHZ Zones. |
Installation Instructions FL12718_R5_II_SS FL 12718 REPORT AND INSTALL DETAILS.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL12718_R5_AE_SS FL 12718 REPORT AND INSTALL DETAILS.pdf Created by Independent Third Party: Yes |